Digital CELEBRIS Pentium PC
Troubleshooting
MCS Logistics Engineering - Nijmegen
69
Computer Troubleshooting
(continued)
Problem
Possible Cause
Action
Computer
operates
incorrectly after
installing
optional SIMMs
SIMMs installed incorrectly.
Did not rerun BIOS Setup utility.
BIOS Setup utility changes not
saved before exiting.
SIMMs have failed.
Remove SIMMs and reinstall.
Rerun BIOS Setup utility.
Rerun BIOS Setup utility and save changes.
Remove SIMMs and reinstall.
Make sure bank 0 is filled with the correct SIMM
size, speed, and type.
Replace SIMMs.
Computer
operates
incorrectly after
installing
optional
external cache
module
External cache module installed
incorrectly.
External cache module has
failed.
Remove external cache module and reinstall.
Replace external cache module.
Computer fails
to retain setup
information
Computer battery has failed.
Replace computer battery.
Computer does
not boot from
an internal
SCSI hard disk
drive
Operating system software is not
installed on the SCSI hard disk
drive.
Requested partition does not
exist.
Computer not configured for
SCSI hard disk drive operation.
Install the appropriate operating system on the
SCSI hard disk drive.
Partition the SCSI hard disk drive and then reload
the operating software.
Run the BIOS Setup utility and set the IDE
controller option to “Disabled.” This disables the
IDE interface.
Note: When both IDE and SCSI hard disk drives
have been installed, the computer uses the IDE
hard disk drive as the boot device.
Summary of Contents for CELEBRIS 5100