The minimum password length is 6 characters. The maximum password length is
16 characters. Passwords are case sensitive.
Configuring the Console Timeout Feature
The Console Timeout feature allows you select a time, in minutes, after which,
if there is no input at the console terminal, the console session is automatically
terminated. If you are connected to the DECagent 90 by a modem, the telephone
line is also disconnected. When you choose this option, the following prompt
appears:
Change Console Timeout? <NO>
If you do not want to change the console timeout value, then press the Return
key. To change the console timeout value, enter Yes (Y) and press the Return key.
If you enter Yes to change the console timeout value, then one of the following
messages, indicating the current status of the console timeout feature, appears:
The console timeout feature is currently disabled.
Enter a non-zero value to re-enable it.
- or -
The current console timeout value is <nn> minutes.
Where nn is the current timeout value (if enabled). If the console timeout feature
is disabled, the console timeout value is zero (0). If the console timeout feature is
currently enabled (that is, has a non-zero value), setting it to zero (0) will disable
it.
Then the following prompt appears:
Enter the console timeout value (in minutes) <nn>:
Where nn is the current console timeout setting. Enter an integer value ranging
from 0 through 720 decimal. This allows the console timeout to be disabled (0) or
set to timeout anywhere from 1 minute to 12 hours.
Note
The console timeout feature is disabled at initial power-up (factory
setting) and when you choose to reset the DECagent 90 to factory settings.
DECagent 90 Management 4–11