Environmental Specifications
The DECagent 90 is designed to operate in an office environment or equipment
room environment, such as telephone closets or satellite equipment rooms. It is
not intended to operate in a sealed environment.
Operating Environment
The following table provides the operating environment specifications:
Condition
Value
Temperature
5°C to 50°C (41°F to 122°F)
Maximum rate of change
20°C/hr (36°F/hr)
Relative humidity
10% to 95% (non-condensing)
Wet-bulb temperature
32°C (90°F) maximum
Dew point
2°C (36°F) minimum
Altitude
Sea level to 2.4 km (8000 ft)
Air flow
Convectively cooled. A minimum of 10 cm (4 in) of space must
be provided on both ends of the unit for adequate air flow.
Shipping Environment
The following table provides the shipping environment specifications:
Condition
Value
Temperature
-40°C to 66°C (-40°F to 151°F)
Relative humidity
10% to 95% (non-condensing)
Altitude
Sea level to 4.9 km (16,000 ft)
A–2 Specifications and Parts