Diagnostics and Test 5-4
5.4
”DATA SCOPE” PRINTOUT (HEX DUMP)
This function prints any incoming character with the corresponding ASCII codes
(hexadecimal), thus enabling a verification of the receiving of the control codes
sent by the system.
Enabling the Data Scope printout:
Switch off the printer, press the INSTALL CARTRIDGE key and keeping the
key pressed switch the printer on again.
Disabling the Data Scope printout:
To interrupt the hexadecimal printing, press the ON LINE key, to start up again
from where the printer left off, press the key once more.
To exit from this type of printout, switch off the machine or make a reset (press
the INSTALL CARTRIDGE key and then also the PAPER MICRO-ADVANCE
key).