10.12 Handling the Optical Components
10.12.2.1 Lens and Scanner Assembly
This procedure consists of two parts. To remove and replace the lens assembly,
perform steps 1–5. Perform all steps to remove and replace the scanner
assembly.
Use the following procedure to remove and replace the lens or scanner
assembly:
Caution:
Use the static mat and wristband and avoid excessive handling.
1. Make sure the power is off and the ac line cord is unplugged.
2. Remove the following components:
a. Upper cover, as shown in Section 10.2
b. Right and left side covers, as shown in Section 10.3
c. VCU, as shown in Section 10.20
d. DCU, as shown in Section 10.19
10–32 Removal and Replacement Procedures and RSL