2.11 INTERFACE
2.11.2 baud
The following values are available from the baud feature of the DEClaser 1100
printer (PPL3) INTERFACE menu:
19200
9600
4800
2400
1200
600
300
The baud selection establishes the baud rate of the serial port. The
printer’s baud rate must match the baud rate of the host system or
data communication equipment where the serial port is connected.
2.11.3 rsmode
The following values, available from the rsmode feature of the DEClaser 1100
printer (PPL3) INTERFACE menu, define the characteristics of the serial
data byte and must match the values of the equipment that the serial port is
connected to:
8S
8SS
7OS
7ES
7OSS
7ESS
8OS
8ES
The following example shows the format:
8OS
where:
8 is the number of data bits.
O means odd parity, E means even parity. If no O or E, no parity
checking.
S 1-S means one stop bit is used.
2.11.4 dtr
The following values are available from the dtr feature of the DEClaser 1100
printer (PPL3) INTERFACE menu:
READY–H
Fix–H
2.11.5 xon/xoff
The following values are available from the xon/xoff feature of the DEClaser
1100 printer (PPL3) INTERFACE menu. Selecting ON, enables XON/XOFF
flow control.
ON
OFF
DEClaser 1100 Printer Control Panel 2–13