ADD UNIT
2–17
HSZ40 Array Controller
CLI Reference Manual
Switches
Table 2–2 lists all switches for the
ADD UNIT
command and shows which switches can be
used with each type of device and storageset. Descriptions of the switches follow the table.
Table 2–2 Switches for the ADD UNIT Command
Switch
RAID
- set
Stripe-
set
Mirror-
set
NoTrans
Disk
Trans
Disk
CD–ROM Pass-
through
PARTITION=partition_number
9 9
9
9
MAXIMUM_CACHED_TRANSFER
9 9
9
9
9
9
PREFERRED_PATH
NOPREFERRED_PATH (Default)
9 9
9
9
9
9
9
READ_CACHE (Default)
NOREAD_CACHE
9 9
9
9
9
9
RUN (Default)
NORUN
9 9
9
9
9
9
WRITE_PROTECT
NOWRITE_PROTECT (Default)
9 9
9
9
9
WRITEBACK_CACHE
NOWRITEBACK_CACHE (Default)
9 9
9
9
__________________________ Note _____________________________
The RUN/NORUN switch cannot be specified for partitioned units.
____________________________________________________________
PARTITION=partition_number
The
PARTITION
switch allows you to set the unit number for a partition on a storageset or
single-disk unit. Use the partition-number to identify the partition for which you are
adding the host-addressable unit number. (Use the
SHOW
command to find partition
numbers for a storageset or single-disk unit.)
MAXIMUM_CACHED_TRANSFER=n
MAXIMUM_CACHED_TRANSFER=32 (Default)
The
MAXIMUM
_
CACHED
_
TRANSFER
switch allows you to set the largest transfer (in blocks)
to be cached by the controller. The controller will not cache any transfers over this size.
Valid values are 1–1024.
Summary of Contents for HSZ40
Page 6: ......
Page 24: ...2 12 ADD RAIDSET See also ADD UNIT DELETE SET RAIDSET SHOW RAIDSET INITIALIZE ...
Page 101: ...HSZ40 Array Controller CLI Reference Manual Glossary ...
Page 112: ......