SELFTEST OTHER_CONTROLLER and SELFTEST THIS_CONTROLLER
2–55
HSZ40 Array Controller
CLI Reference Manual
IMMEDIATE_SHUTDOWN
NOIMMEDIATE_SHUTDOWN
The IMMEDIATE_SHUTDOWN and NOIMMEDIATE_SHUTDOWN switches are used
to instruct the controller when to shutdown when running the self-test program.
_________________________Caution____________________________
The IMMEDIATE_SHUTDOWN switch instructs the controller to immediately
shutdown, without regard to any data contained within write-back cache.
____________________________________________________________
Select IMMEDIATE_SHUTDOWN to instruct the controller to run the self-test program
immediately without checking for online devices or without flushing user data from write-
back cache to devices.
Select NOIMMEDIATE_SHUTDOWN to instruct the controller to flush data from write-
back cache before running the self-test program.
Examples
To start the self-test on T
HIS
_
CONTROLLER
, as long as it does not have any units online:
CLI> SELFTEST THIS_CONTROLLER
To start the self-test on the O
THER
_
CONTROLLER
even if the controller cannot flush all data
from the write-back cache:
CLI> SELFTEST OTHER_CONTROLLER IGNORE_ERRORS
See also
RESTART OTHER_CONTROLLER
RESTART THIS_CONTROLLER
SHUTDOWN OTHER_CONTROLLER
SHUTDOWN THIS_CONTROLLER
Summary of Contents for HSZ40
Page 6: ......
Page 24: ...2 12 ADD RAIDSET See also ADD UNIT DELETE SET RAIDSET SHOW RAIDSET INITIALIZE ...
Page 101: ...HSZ40 Array Controller CLI Reference Manual Glossary ...
Page 112: ......