Introduction to the CLI
1–3
HSZ40 Array Controller
CLI Reference Manual
Accessing and Exiting the CLI
__________________________ Note _____________________________
The maintenance terminal port on the controller is meant to be used only for
initial configuration and required maintenance functions. Operation of this port
may cause harmful radio frequency interference. Always disconnect the terminal
and cable when you have finished working with the controller.
____________________________________________________________
You can access the CLI from a maintenance terminal connected to the front bezel of the
controller (local connection) or through the host operating system using a VAXcluster™
system console (VCS), a diagnostic and utility protocol (DUP), or an HSZterm (remote
connection). You must use a local connection to perform initial controller configuration,
such as setting the controller ID. Once you have completed initial configuration and the
controller is visible on the host bus, you can perform all other configuration through a
remote connection.
In a dual-redundant controller configuration, you can view and set the configurations of
both controllers with one local or remote connection. Use T
HIS
_
CONTROLLER
commands to
change the configuration on the controller that is running the CLI session. Use
O
THER
_
CONTROLLER
commands to view or change the configuration on the partner
controller.
If you are using a remote DUP connection to the CLI, enter the
EXIT
command at the CLI
prompt to close the connection. You do not need to exit from a local connection.