5-38
d. HDLSI
An internal timer is started by HDLSI after the alarm signal is received and the PWSTOP signal is output to
the power supply after counting up.
If the PWSTOP signal is output, the power supply (+34 V and +5 V circuits) is turned off to keep the SP and
LF motors from burning out.
Short-mode
detection
+34V
+34V
+34V
SG2
Long-mode
detection
SG2
SG1
SG1
Time
constant
circuit
SG1
+5V
+5V
+
–
SG1 SG1
SG1
Time
constant
circuit
Detection circuit
+5V
+5V
+
–
SG1
Compare circuit
Compare circuit
Detection
circuit
HDLSI
LGHIC
MBCV20050
624µs
timer
7s timer
27s timer
SPALMS
LFALMS
SPALML
LFALML
LS06
PWSTOP
Figure 5.38 Fire check circuits