4-32
4.9.2
Adjustment
(1) Print head gap adjustment
When replacing the carriage unit or platen, check that the gap between the print head and platen is 0.38 ± 0.03
mm at both ends of the platen. To check the gap along the platen, use a platen gap adjustment gauge and move
the carriage to the left and right. To adjust the gap, turn the two levers at the ends of the stay shaft.
Procedure
1.
Turn off the printer power switch.
2.
Remove the covers (Section 4.9.1(3)).
3.
Set the paper thickness lever upward (narrowest).
4.
Calibrate the platen gap adjustment gauge according to its instruction manual.
5.
Remove the print head if it is on the carriage unit, then install the gauge instead.
6.
Turn the platen and find the rotational location where the print head gap is widest.
Head gap gauge
Summary of Contents for LA30 N
Page 1: ...Order Number ER LA30N SV 003 Service Manual TM LA30N LA30W Companion Printer...
Page 2: ......
Page 5: ......
Page 39: ...3 16...
Page 91: ......
Page 137: ......
Page 140: ......
Page 141: ...TM Printed in Ireland...