fault messages
66
Operator’s Guide
CLEAR PAPER JAM
Clear jam and reload paper (see page 56
). If
this message recurs, contact your Digital
Customer Service Engineer.
CLOSE PLATEN
The forms thickness lever is open. Close
the forms thickness lever.
COIL HOT
One or more hammer coils are
overheating. Contact your Digital
Customer Service Engineer.
CTL VOLT FAIL*
Controller voltage failure. Contact your
Digital Customer Service Engineer.
DRVR CIR BAD*
Hammer coil count test failed. Contact
your Digital Customer Service Engineer.
ENERGY STAR
Status message: printer is in low–energy
idle state, all fans and higher voltages
are off, only+5Vdc logic circuits are
active. No action required.
EXHAUST FAN FLT
Sensors cannot detect current in fan
circuit. Power off the printer and remove
the paper path. Check that the fan cable
connector is connected. Check for
obstruction of vents and fan airway, and
remove any obstructions. Check for items
beneath the printer blocking cabinet vents.
Power back on the printer. If this message
recurs, contact your Digital Customer
Service Engineer.
CLOSE PLATEN
COIL HOT
CTL VOLT FAIL*
DRVR CIR BAD*
EXHAUST FAN FLT
ENERGY STAR
CLEAR PAPER JAM