Graphic Touchscreen Keypad User Guide
9
Instant Zone
Exterior windows and non-entry doors, or interior protection
devices, are typically not programmed with delay times. If these
zones fault while the system is armed, an alarm occurs instantly.
24-Hour Zone
A 24-hour zone is not turned on or off by arming or disarm ing your
system. Some examples of 24-hour zones are fire zones, panic
zones, and temperature control zones.
Areas
An area is made up of burglary zones that can be armed or disarmed
together. The Perimeter area, for example, consists of all the doors
and windows on the outside of the building. When you arm the
Perimeter, these zones sound an alarm if tripped.
Central Station Monitoring
Your system can also be programmed to automatically send alarm,
trouble, and arming and disarming reports to a Central Station.
Operators at the Central Station can then dispatch the appropriate
authorities or contact you with the specific event information.
Status
Status displays the system armed or dis armed status at the keypad
and on the upper right corner of the Main Screen. Alarm or trouble
con ditions on a zone or a system monitor such as AC or battery
trouble can also display. There are two types of status information
available:
Status List
and
Armed Status
.
Status List
The Status List displays on the Keypad screen any alarm or trouble
condition on a zone and any trouble condition that occurs with
the AC power or battery power. If your system contains any Panic
zones, these do not display on the screen for security reasons.
If an alarm occurs on a non-fire, 24-hour zone or a system monitor,
it remains in the Sta tus List until it re stores. If one or more armed
burglary zones trips, the last one to trip remains in the Status List.
The burglary zone alarm remains in the Status List until it is cleared
by disarming the system. Pressing
CMD
allows the next status list
item to be displayed
Zone Status
To display the status of a particular zone, Press
Keypad
on the
Carousel Menu to display the Keypad screen. Enter the zone number
followed by
CMD
when the screen displays the
Status
List.
Armed Status
With
Armed
status, the screen displays the current armed condition
of areas within your security system.
The screen displays
When
HOME SYSTEM ON
The perimeter is armed in a
Home/Away
system.
PERIMETER ON
The perimeter is armed in an
All/Perimeter
system.
ALL SYSTEM ON
All areas are on.
SLEEP SYSTEM ON
The perimeter and interior areas are on
but the bedroom area is off.
Exit Error
This is an automatic panel function that occurs if an exit door does
not close completely after the system is armed.
For example, if the front door is left ajar upon exit and the exit delay
time expires, the system attempts to arm the front door zone but
recognizes the open condition. The system sounds the alarm sirens
and starts the entry delay. If the open condition is not corrected, an
alarm and exit error is reported to the Central Station.
Exit Error
allows the Central Station to acknowledge the arming
error without dispatching the police on a false alarm.