DL-SE3H1V-C Owners Manual
19
Relay Port Control / Configuration
Description
Command
Example
Turn Relay Power On / Off
SET RELAY_PWR
{x}
rx
{x}
= [on, off]
Command:
SET RELAY_PWR on rx<CR><LF>
Return:
RELAY_PWR SET ON RX<CR><LF>
Set Relay Mode
SET RELAY_M
{m}
rx
{m}
= [latch, momentary]
Command:
SET RELAY_M latch rx<CR><LF>
Return:
RELAY_M SET LATCH RX<CR><LF>
Query Relay Mode Type
GET RELAY_M rx
Command:
GET RELAY_M rx<CR><LF>
Return:
RELAY_M GET LATCH RX<CR><LF>
Set Relay Momentary Time
SET MOMENT_T
{t}
rx
{t}
= [1-10]
Note: Maximum time is 10 seconds
Command:
SET MOMENT_T 5 rx<CR><LF>
Return:
MOMENT_T SET 5 RX<CR><LF>
Query Relay Momentary
Time
GET MOMENT_T
{t}
rx
Command:
GET MOMENT_T rx<CR><LF>
Return:
MOMENT_T GET 5 RX<CR><LF>
Relay ports can be set to either momentary or latching operation modes.
When setting relay mode to momentary, use the [
SET MOMENT_T
{t}
rx]
command to set the relay power
time settings in seconds.