background image

DVR Operating

Start and Stop Recording

To start recording, move the switch to «ON». The LED flashes five times, and the 
recorder starts recording. During recording DVR indicates battery charge level and free 
memory space by 2 series of LED flashes.
The first series of flashes indicates the battery charge level at the moment of recording 
start (for models powered by batteries) or current rechargeable battery charge level (for 
models powered by rechargeable batteries):
1 flash – (almost) fully charged battery (80-100% charge)
2 flashes – enough to work (20-80% charge)
3 flashes – almost discharged battery (0-20% charge)
T

  he second series 

 

 of flashes indicates free memory available:

1 flash – 100-76%
2 flashes – 75-51%
3 flashes – 50-26% 
4 flashes – 25-1%
The interval between the first and second series of flashes is approximately 4 seconds, 
and between the second and first is about 8 seconds.
Attention! In recorders powered by batteries the first series of flashes shows battery 
charge at the time the recorder has been activated and is not controlled during recording.

If LED flashes slowly 3 times after turning on, it means that the battery or 
rechargeable battery is fully discharged. If LED flashes quickly 3 series by 3 times 
each after turning on, it means that there is no free memory space.

To stop recording, move the switch to «OFF» position. The LED flashes once for 10-12 
seconds and the recorder stops recording.

After stopping, the DVR goes to stand-by mode. In stand-by mode the DVR has low 
power consumption and does not demand battery replacement or rechargeable battery 
charging (depending on the model) for a long period time.
If there is not enough memory to continue the recorder or battery/rechargeable battery is 
discharged while recording, the record is stopped and DVR turns to stand-by mode 
automatically.

Attention:

• Avoid using the recorder with nearly discharged battery, otherwise it may turn off at 
the wrong moment.
• The higher the record's sampling rate, the more energy is consumed by the recorder. At
the frequency of 22 kHz the consumption is twice higher than at 8 kHz, and for the 
recorders with batteries the autonomy is down by more than three times.
• Fast switching during recording (On → Off → On) puts the tab which is visible in the 
Sound Processor program. Thus it is possible to mark the desired parts of records and 
then quickly find them.
• Fast switching when the recorder is off (Off → On → Off) shows battery charge level 
the and free memory capacity through flashing of LED. For this indication, see «Start 
and Stop Recording.»

5

Summary of Contents for EDIC-mini Tiny+

Page 1: ...Digital Voice Recorder DVR EDIC mini Tiny EDIC mini Tiny16 Operational Manual Version 02 15 Digitaltech Market...

Page 2: ...nd stop recording 5 Playing back audio recordings 6 Downloading from the B70 recorder 6 Setting Microphone Amplification for Tiny16 7 The Timers 7 The Voice Activating System VAS 7 Loop recording mode...

Page 3: ...recording at the preset time using timer Due to the absence of removable elements the recorder is operational under wide temperature ranges when shaking or dusted The LED indicates operating modes of...

Page 4: ...8 7 5 Tiny B74 35 20 14 12 Tiny B76 35 24 14 12 Tiny A77 58 55 45 30 Model Sample rate kHz 8 11 13 3 20 Tiny16 A75 50 46 44 30 Tiny16 S78 56 48 43 30 Installing and replacing batteries Before starting...

Page 5: ...d If LED flashes quickly 3 series by 3 times each after turning on it means that there is no free memory space To stop recording move the switch to OFF position The LED flashes once for 10 12 seconds...

Page 6: ...l to the right one Attention Do not disconnect the recorder while performing any operations in the EMPlus program This can cause data corruption during such operations the recorder s LED is flashing W...

Page 7: ...op 13 05 with these settings the recorder starts recording every day at 9 20 and stops recording at 13 05 Recording will be carried out as long as the recorder has free memory enough charge and as lon...

Page 8: ...do not forget to press the button Apply changes to the Recorder After disconnecting the recorder off the PC enable recording and place it in the conditions similar to the planned recording for exampl...

Page 9: ...covered by the warranty DVR s settings With the EMPlus program you can set all the necessary parameters of the recorder such as turning on and setting Timers turning on and setting VAS turning on and...

Page 10: ...ps recording and goes to PC connection mode The detailed description of EMPlus program is given in the EMPlus Manual located inside DVR s memory Technical Support The technical support is always avail...

Page 11: ...n for the recorders with batteries Press the Reset button for 2 3 seconds for the recorders with rechargeable batteries 10 flashes of LED after enabling recording When enabling recoding the recorder w...