MIDI MESSAGES
MIDI PARAMETER EDIT
format:
Example:
procedure number 60h
60
effect number
01
style number
01
parm number
01
value MSB (0,0,0,0,0,0,value lo.7,value hi.7)
00
value hi (6-0 bits)
00
value lo (6-0 bits)
10
Example:
F0 00 00 10 00 36 60 01 01 01 00 00 10 F7
; parm edit effect 1, detune, parm 1, Packed value
MIDI SysEx Message Format:
F0
00 00 10 00
36
60 01 01 01 00 00 10
F7
Universal
DOD
SysEx Vocal- Value End
SysEx
Manuf.
Chan- Iist Work- Parm
of
Header
ID
nel
station EX ID Edit
Message
MIDI QUERY: QUERY
format:
procedure number 5Eh
query type (0=front panel, 1=edit buffer)
Example:
F0 00 00 10 00 36 5E 00 F7; SYSEX query (front panel)
F0 00 00 10 00 36 5E 01 F7; edit buffer
MIDI QUERY: RESPONSE
format depends on the query type
format (front panel) :
procedure number 5Dh
PACKED {
query type (0=front panel)
data size hi (00h)
data size lo (56h)
character set (1 byte)
LCD buffer (80 bytes)
levels
.7-.4 return levels
.7-.4 input levels
LED state (2 bytes)
.1=bypass
.2=factory
.3=user
.4=song
.5=utility
.6=edit
}
format (edit buffer) :
procedure number 5Dh
PACKED {
query type (1=edit buffer)
data size hi
data size lo
data
}
Example:
F0 00 00 10 00 36 5D ... packed data ... F7 ; SYSEX query
response
DEVICE INQUIRY: QUERY
format:
procedure number 7Eh (universal system exclusive non
real time header)
channel number xx (with 7FH, device responds no
matter what sys chan)
general info id 06
device inquiry message id 01
Example:
F0 7E 7F 06 01 F7
DEVICE INQUIRY: RESPONSE
format:
procedure number 7Dh (universal system exclusive
non real time header)
channel number xx
general info id: 06
device id response message: 02
manufactures id: 00 00 10 (DOD Electronics)
device family code (36h,00)
device member code (00, 00)
software version id (integer, fraction, 0, 0)
Example:
F0 7E xx 06 02 00 00 10 36 00 00 00 02 01 00 00 F7 ;
Vocalist Workstation EX 1.0
Summary of Contents for VOCALIST Workstation EX
Page 1: ...VERSION EX 1 2...