background image

Model: db Enline 

P a g e  | 

4

 

 

Drill the cabinet where you have marked the cable passageway, so that the cables can be 

passed directly into the rear of the db Enline unit. 

 

 

Mount  the  back  plate  of  the  db  Enline  unit  to the  cabinet  using the  supplied  mounting 

hardware. 

 

 

The Enline unit attaches directly to the Digitus db Bus. Pass the db Bus cables from the 

inside of the cabinet, through the cable pass-through hole. 

 

Summary of Contents for db Enline

Page 1: ...db Enline Installation and User Manual ...

Page 2: ...Model db Enline P a g e 1 TABLE OF CONTENTS db ENLINE OVERVIEW 2 INSTALLATION THE db ENLINE UNIT 3 SUGGESTED WIRING CONFIGURATION 6 USING THE db ENLINE UNIT 7 ...

Page 3: ...d in the db ServerRack End of row solution as a user input device The unit allows a user to specify which door they are attempting to access and then allows them to authenticate their credentials PIN Fingerprint RFID If the user enters a valid door number and has access to the door at the time of requesting access the door will unlock ...

Page 4: ... prior to marking by using a torpedo level Drill the cabinet where the 4 mounting screws are to be fixed It s important to record the serial number and location of each db Enline Unit installed The db Enline s serial number is used to identify it within the Digitus DAS SQL software There is no limit to the number of db Enline units that can be installed on a db Bus as long as db Enline Units Remot...

Page 5: ...les can be passed directly into the rear of the db Enline unit Mount the back plate of the db Enline unit to the cabinet using the supplied mounting hardware The Enline unit attaches directly to the Digitus db Bus Pass the db Bus cables from the inside of the cabinet through the cable pass through hole ...

Page 6: ...ckets as shown in Figure 1 Figure 1 Route the cables as shown in Figure 2 Figure 2 Insert the 4 mounting lugs on the front section of the db Enline unit into the 4 mounting holes on back section of the db Enline unit Secure the db Enline unit with the 4 supplied screws ...

Page 7: ... The diagram below shows a top down view of a row of server cabinets The db Bus Controller is located in the far left cabinet with a Remote Node and all other cabinets contain just a Remote Node The db Enline Unit is installed on the outside of the far right cabinet Figure 3 Refer to the db ServerRack Bus Controller manual for db Bus Controller and Remote Node installation ...

Page 8: ...oor Number Door Number only The number is digits required for each item is set through the DAS SQL Management Software The square brackets indicate the number of digits required Leading zeros are required to ensure the correct number of digits e g If the requested Row is 3 and the required number of digits is two the row number should be entered as 03 Key Requirement The db Enline can be configure...

Page 9: ... the DAS SQL Management Software The user must provide the credentials as requested by the db Enline unit User is required to enter User is required to place a 4 digit PIN number finger on the scanner Access Granted Denied Based on verification of the credentials access is either granted or denied Access Granted Access Denied Following a successful access the specified door will unlock Time Restri...

Page 10: ...Model db Enline P a g e 9 Digitus Biometrics Inc 2 East Bryan Street Suite 502 Savannah GA 31401 USA Phone 912 231 8175 Fax 912 629 9478 www digitus biometrics com support digitus biometrics com ...

Reviews: