accordance with “OPU” function. The provided voltages are
208v, 220v, 230v, 240, you can choose anyone of them by
yourself (The default is 220v).
③
Confirm the output voltage selecting interface. After
selecting numerical value, press and hold the function
setting key
for more than half a second (less than
2 seconds). Now, the OPU setting function is completed and
the numerical value below the “OPU” will light without
flashing.
④
Exit from the setting interface. Press and hold function
setting key
for more than half a second (less than
2 seconds), exit from the setting interface and return to
main interface.
Battery Pack
number and
type setting (4)
①
Enter the setting interface. Press and hold the function
setting key
for more than 2 seconds, then come to setting
interface, Press and hold the scroll key
for more than half
a second(less than 2 seconds), select the function setting,
choose battery setting interface, at the moment, the letters
“bAt” will flash.
②
Enter the battery setting interface. Press and hold the
function setting key
for more than half a second(less than
2 seconds), then come to setting interface of battery, the
letters “bAt” will stop flashing. The numerical value below
the “bAt” will flash. Press and hold the scroll key
for more
than half a second (less than 2 seconds), select the
numerical value in accordance with the actual number of
connected external battery packs.
③
Confirm the battery strings setting interface.
After selecting numerical value, press and hold the function
setting key
for more than half a second (less than 2 seconds).
Now, the battery strings setting is confirmed and the battery
type value below willflash.
④
Set the battery type in the same way.
⑤
Exit from the setting interface. Press and hold function setting
key
for more than half a second (less than 2 seconds), exit
from the setting interface and return to main interface.