Load segment
setting (5)
①
Enter the setting interface. Press and hold the function
setting key
for more than 2 seconds, then come to setting
interface, Press and hold the scroll key
for more than half
a second (less than 2 seconds), select the function setting,
choose battery setting interface, at the moment, the letters
“Seg 1” will flash.
②
Enter the load segment setting interface. Press and hold the
function setting key
for more than half a second(less than 2
seconds), then come to setting interface of load segment, the
letters “Seg 1” will stop flashing. The numerical value below
the “Seg 1” will flash. Press and hold the scroll key
for more
than half a second (less than 2 seconds), select the battery
voltage, 10.5v, 11.0v, 11.5v(default is 10.5v).
③
Confirm the power shedding shielding battery voltage
setting. After selecting numerical value, press and hold the
function setting key
for more than half a second (less
than 2 seconds). Now, the load shielding battery voltage
setting is confirmed.
④
Exit from the setting interface. Press and hold function
setting key
for more than half a second (less than 2
seconds), exit from the setting interface and return to main
interface.
Automatic
Battery Test
mode
setting (6)
①
Enter the setting interface. Press and hold the function
setting key
for more than 2 seconds, then come to
setting interface, Press and hold the inquiring key
for
more than half a second(less than 2 seconds), select the
function setting, choose Automatic Battery Test setting
interface, at the moment, the letters “Abt” will flash
②
Enter the “Abt” setting interface. Press and hold the
function setting key
for more than half a second(less
than 2 seconds), then come to setting interface of “Abt”, at
this time, the letters “Abt” will light for a long time. The
“ON”(or OFF) below the “Abt” will flash. Press and hold the
inquiring key
for more than half a second (less than 2
seconds) to determine whether the “Abt” function is used or
not. If used, the corresponding word is “ON”, if not, the
word is “OFF”. It can be determined by yourself.
③
Confirm the “Abt” selecting interface. After selecting ON or
OFF, press and hold the function setting key
for more
than half a second (less than 2 seconds). Now, the “Abt”
setting function is completed and the “ON” or “OFF” below