FAULT AND MAINTENANCE OF MEDIA CONVERTERS
Fault
description
Cause description
Maintenance
POWER
LED Lamps
are off
Haven’t connected the power
plug or not a valid connection
Connect the power plug and make
sure it is a valid connection
Link/Act LED
Lamp is off
1. Haven’t connected the
electrical cables to the
electrical port or not
a valid connection
Connect the electrical cables to the
electrical port and make sure it’s a
valid connection
2. Used the wrong electrical
cables for electrical
connection
Use right type of electrical cables
for electrical connection
3. Any fault with the NIC and
the terminal of Ethernet
To make sure the NIC and the
terminal of Ethernet can work
normally
FX and
FX-link/Act
LED Lamps
are off
1. There might be any fault with
the terminal optical devices
Check the terminal optical devices
and the main fiber to see if they can
work normally. If not, then maintain
them
2. The optical fiber has broken
down or the connection of
optical fiber is not valid
3. The optical fiber is over-loss
TX and FX
LED Lamps
are normal
but the data
can not be
transmitted
1. The connection between
optical fiber and devices is
not valid, this will cause the
TX power not strong enough
1. Check the fiber connectors and
make sure the connection
between optical fiber and
devices is valid
2. The system get power just for
a little moment or any
changes for the network,
these may cost a little time
for media converters to adapt
2. If this option can still not work a
long time after all installations,
then stop the power supply, wait
a little moment and try again
with the power on
Hereby Assmann Electronic GmbH, declares that the Declaration of Conformity is part of the
shipping content. If the Declaration of Conformity is missing, you can request it by post under
the below mentioned manufacturer address
www.assmann.com
Assmann Electronic GmbH
Auf dem Schüffel 3
58513 Lüdenscheid
Germany