1.2 Installation 

Vertical-mounting (0U) 
 

1.3 Function Description

 

There are four series for the Smart PDU range. A, B, D series function comparison table: 

 

 

A series 

B series 

D series 

Input-level Metering 

(A/V/VA/kWh/Power factor)   

Yes 

Yes 

Yes 

Individual Outlet Metering 

No 

Yes 

Yes 

Individual Outlet Switching 

No 

No 

Yes 

 

A series: DN-95624/ DN-95625/ DN-95640/ DN-95641/ DN-95642 
B series: DN-95628 
D series: DN-95632/ DN-95634/ DN-95643

 

2. Hardware Introduction 

2.1. System initialization 

The buzzer sounds when the SMART PDU is switched on and it stops after 3 seconds.   
Then the LCD screen is lighted after 6 seconds with the following information displayed: 
 

 

 

 

 

               Vertical (0U)                               Horizontal (1U) 

 
Note: 192.168.1.163 is the default IP address; and this is the first page after system initialization. 
 

 

 

  15:53:58 
  2015-04-21 
192.168.1.163 

 

(Device time) 
(Date) 
(IP address) 

 

  15:53:58 
  2015-04-21 

 

Summary of Contents for DN-95624

Page 1: ...Smart Power Distribution Unit QIG DN 95624 DN 95625 DN 95628 DN 95632 DN 95634 DN 95640 DN 95641 DN 95642 DN 95643 ...

Page 2: ...hock when you cannot verify grounding Reconnect the PDU to the power outlet only after you make all connections Operation under unfavorable environmental conditions must be avoided Humidity over 80 relative wet ambient temperatures above 50 C solvents flammable gases dust vapors If external damage to this PDU is detected do not operate this PDU Take this PDU immediately out of service if external ...

Page 3: ...tor 10 RESET button 11 USB port for WIFI access or software upgrade 12 NET 10 100M Ethernet communication port 13 SER Serial communication port support MODBUS 14 IN for daisy chain 15 OUT for daisy chain 16 T H1 temperature and humidity sensor port 1 17 T H1 temperature and humidity sensor port 2 18 SENSOR extend sensor hub communication port sensor hub support 2 temperature humidity sensor 2 door...

Page 4: ... 95624 DN 95625 DN 95640 DN 95641 DN 95642 B series DN 95628 D series DN 95632 DN 95634 DN 95643 2 Hardware Introduction 2 1 System initialization The buzzer sounds when the SMART PDU is switched on and it stops after 3 seconds Then the LCD screen is lighted after 6 seconds with the following information displayed Vertical 0U Horizontal 1U Note 192 168 1 163 is the default IP address and this is t...

Page 5: ...e part number CPU ARM926EJ S means the type of the device CPU chip Version 1 0 0 is the software version number M S Master means the Master Unit and Slave 1 means the Slave unit 1 1 4 means the order of Slave unit Type 3 phase C means the device is 3 phase C series one Through the DOWN or UP key to scroll down or up to the next previous page turn to the main menu and select the second item Total t...

Page 6: ...n to the main menu and then press DOWN key to select Temp Hum to view the temperature humidity as below Press ENTER to return to the main menu and then press DOWN key to select Sensors to view the door water logging and smoke sensor status as below Press ENTER to return to the main menu then press DOWN key to select Output to view each individual outlet current as below U 214V I 00 0A P 0 000kW E ...

Page 7: ...vides a lot of network services like WEB server SNMP Telnet SMTP and NTP It s easy to do second development and software integration 3 2 Access method Web based can access via browsers like Internet Explorer Google Chrome and Fire fox supports WIFI including the mobile device like smart phone and tablet SNMP v1 v2c v3 Telnet and Serial console like MODBUS 3 2 1 Web access Open a browser and enter ...

Page 8: ...logo and function menus and language selector Device information display device name device series and device status and function level Output status display output name on off state individual current individual power power factor and environment status From the drop down menu of device to check the information of Slaves More detailed information on operating and configuring the device can be fou...

Page 9: ...31 24way D Series DN 95632 24way DN 95633 16way DN 95634 24way Output voltage 110 220VAC 50 60 Hz Output current 16A 32A 3 Control ports Net port 1 RJ45 port Daisy chain port 2 RJ45 port Software update port 1 RJ45 port Temperature humidity port Max 2 RJ11 port can add more Smoke sensor port Max 1 RJ11 port optional Water sensor port Max 1 RJ11 port optional Door sensor port Max 1 RJ11 port option...

Page 10: ...CD 10 Optional fittings Sensor Temperature humidity sensor Smoke sensor Door sensor Water logging sensor 11 Environment Working Environment Temperature 0 45 Relative humidity 30 90 Storage Environment Temperature 20 70 Relative humidity 0 95 12 ROHS Compliance This is a Class A product In home environment this product may cause radio interference In this case the user may be required to take appro...