Bullseye

 

Piezo User Manual

 

 

 

 

Software Version K19L16 

 

YOU MUST READ THIS 

MANUAL BEFORE USE 

Summary of Contents for Bullseye Piezo

Page 1: ...Bullseye Piezo User Manual Software Version K19L16 YOU MUST READ THIS MANUAL BEFORE USE...

Page 2: ...ghts reserved TABLE OF CONTENTS Section 1 OVERVIEW 3 Section 2 QUICK START GUIDE 4 Section 3 MENU SETTINGS FLOWCHART 5 Section 4 WHY PIezo 6 Section 5 DISPLAY OPTIONS 7 Section 6 service and maintenan...

Page 3: ...wing points of inflection and small changes in pressure with sub second resolution Portable Rugged design for field or laboratory use Dimensions 6 2 x 3 7 x 1 3 Only requires 4 AA alkaline or Micro B...

Page 4: ...tart guide or this user manual Setting Up the Bullseye Piezo 1 Power Your gauge comes with 4 Pre installed AA batteries Alternatively you can power by attaching a Micro B USB power cable To change Bat...

Page 5: ...2 7 6 5 0 9 0 0 s a l e s d i g i v a c c o m w w w d i g i v a c c o m Copyright 2020 DigiVac Inc All rights reserved Feel free to explore the latest copy of this manual at www digivac com for all th...

Page 6: ...SURE BOTH PRESSURE AND ROUGH VACUUM Our specialized piezo sensors allow you to easily measure both Piezoresistive sensors have exceptional durability combined with low cost and better than 1 full scal...

Page 7: ...olated sensors where the silicon die of the piezo resistive encounters clean dry gasses like air and nitrogen will work These electronics can survive a lifetime exposed to clean dry air and even low h...

Page 8: ...selected from the display menu and numeric formats are selected from the Setting option Display The SEL button enters and traverses the Settings menu The numeric display shows the currently configure...

Page 9: ...l showing noise This noise comes from the instrument s process of measurement as well as the vacuum system under measurement In this sense the auto scaling graph is a data visualization microscope Use...

Page 10: ...t The numeric display shows the currently configured units in these examples the vacuum pressure unit is Torr In any display mode the UP and DOWN buttons turn the backlight on and off respectively the...

Page 11: ...ensor be checked regularly and cleaned as needed Is you would like to review how to clean a sensor you can find one on thermocouple sensor cleaning here Bluetooth Models Operation For Bluetooth Models...

Page 12: ...ion is typically a worst case scenario as drift is not easily predicted and depends on operating environment DigiVac offers calibration services including NIST calibration which provides vacuum data o...

Page 13: ...er These numbers on the bottom represent the digital calibration points to be adjusted in order to achieve optimal calibration There are 2 ways to calibrate Manually and Automatically Press the circul...

Page 14: ...o m Copyright 2020 DigiVac Inc All rights reserved The screen will go negative when the up and down arrows are pressed simultaneously to indicate the success of the button push Section 7 Accuracy Inst...

Page 15: ...h for portability and field use Stability 0 25 per year Proof Pressure 60 PSI Burst Pressure 200 PSI Section 9 Units of Measurement This instrument is calibrated in microns or millitorr Understanding...

Page 16: ...P KF25 Y 1 8 FNPT to KF25 Adaptor barb adaptor ADP 1 4 Y 1 8 FNPT to ID hose barb 5 16 barb adaptor Adp 5 16 Y 1 8 fnpt to 5 16 id hose barb 3 8 barb adaptor Adp 3 8 Y 1 8 FNPT to 3 8 ID hose barb Sec...

Page 17: ...entify vacuum pressure trends Graphical display for quick determination of vacuum level Android Links via Bluetooth Low Energy to Bullseye Piezo with Bluetooth to view alarm log readings and email dat...

Page 18: ...LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE NON INFRINGEMENT OR ANY OTHER WARRANTY EXPRESSED OR IMPLIED Limitation Of Liability You agree and acknowledge DIGIVA...