background image

P750LV2.1 industrial gate motor manual  

 

13 

 

 
 
 

 

1. Orders 

 

The placement of any orders upon Digiway implies acceptance of these terms and 
conditions and takes precedence over any other terms and conditions written or oral. 

 

 
2. Deliveries

 

(a) Time of delivery will be complied with wherever possible. It is not guaranteed and 
is subject to extensions to cover delays caused by strikes, vehicle breakdown, traffic 
delays, weather and any causes beyond Digiway’s control. 

 

(b) The Purchaser shall not be entitled to be compensated for any loss or damage due 
to any of the causes stated.  
(c) Most of the motors are stock items, but temporarily runs out of stock. Restock 
time can experience of approximately 8-12 weeks from receipt of official written 
order. 

 
3. Warranty 

 

(a)

 

Digiway has 12 months return base warrants from date of purchase in normal use 
condition.  

(b)

 

Digiway  control  boards  can  be  up  to  two  years warranty.  subject  the  application 
conditions.  

(c)

 

In lieu of all other warranties expressed or implied. Digiway shall not be liable for 
any  special  indirect,  incidental  or  consequent  damages  of  any  kind  or  nature. 
Equipment manufactured and installed by it to be free from defects in material and 
workmanship for. Digiway will repair or replace at its option any product or part 
which it determines to contain defective material and workmanship. Defective parts 
must be returned to Digiway for repair or replacement. Costs associated with the 
return of the goods will be the responsibility of the sender. On site repairs will incur 
travel and labor charges. Liability for replacement parts or repairs carried out by 
Digiway does not extend the original twelve-month warranty period.  

 
4. Payment 

 

(a) Unless agreed expressly in writing, otherwise the terms of payment shall be made 
prior to shipment or where agreed on completion of the installation. Methods of 
payment are by:  
 (i) Direct bank transfer with remittance advice supplied from purchaser.  
(ii) Cheque’s need to be received and cleared before shipment.  
  

5. Returns 

 

Returns only accepted within 14 days of invoice. Credits only paid after inspection of 
goods. All returns subject to 30% re-stocking fee on product. Damaged goods are 
subject to further charges to the value of the damage.  

 

 

CONDITION OF SALE

 

 

Summary of Contents for P750L

Page 1: ...P750LV2 1 industrial gate motor manual 1 P750L Sliding Gate Motor Version V2 x INSTRUCTION MANUAL IMPORTANT SAFETY WARNING ...

Page 2: ...ON Additional safety device MUST be fitted such as Photo Electric Beam Loop Detectors ATTENTION Before do the manual release the mains power switch must be off even there is no power ATTENTION Before power on the manual release MUST engaged ATTENTION Gate opened stopper and closed gate stopper MUST be installed Contains 1 General description 3 2 Specifications 3 3 Control Board Layout 4 4 DIP swit...

Page 3: ...V2 1 industrial gate motor manual 3 Fig 1 1 AC6 Control Board 2 Mounting Plate 3 Terminals 4 Limit switch 5 Manual Release 6 Transformer 7 Inverter VSD 8 EMC filter 9 Electric motor 10 Gearbox GENERAL LAYOUT ...

Page 4: ...1 5mm thickness has remove door P750 and plenty of room for the access control accessories including din rail mounting 50VA transformer 12V 24v 2A can directly drive magnetic lock warning lights etc Technical Specifications Power supply 230 240V AC at 10A Output voltage 230V AC three phase via inverter Max 0 75KW or 1 5KW Motor rate Three phase two poles 0 75KW Gate type Track or cantilever Drive ...

Page 5: ...en by motor1 in the case of single speed mode or partly opens gate in the case of sliding gate mode How far the gate will open depending on the Pedestrian Open Time this can be changed by user If P E input is activated during the gate is closing the gate will reopen for another Pedestrian Open Time P E Close setting and Auto Close setting will also apply to pedestrian cycle 2 2 3 Close Terminals i...

Page 6: ...is ON the PE beam will work on the open cycle and close cycle DIP6 is off the PE beam will work only in close cycle 2 3 6 NOLS DIP7 ON N O limit OFF N C limit DIP7 is ON the limit inputs change to N O and DIP7 is off the limit inputs are N C 2 3 8 Security close DIP8 ON SEC CLS OFF NO SEC CLS DIP8 is on and P E input is active while the gate is opening if the PE clear the gate controller stops gat...

Page 7: ...ull close run time setting Pedestrian running time Push and hold on PED for the pedestrian open run time setting Sync delay time Motor2 delay time Push and hold on STP for the sync delay time setting Auto close time set Push and hold on OSC for the auto close time setting PE close time set Push and hold on PEB for the PE close time setting 2 5 2 SET2 time setting Turn SET1 off and SET2 on Warn tim...

Page 8: ...which plugs into the control board the control board will control light which will illuminate the driveway etc The light will automatically turn off after preset time customer programmable If DIP4 is set to ON the M2 output will change to light output 4 Audio warn output On Board buzzer can give warn for diagnose Additional buzzer or relay module which plugs into the control board the control boar...

Page 9: ...Main Freq Source 1 0 00 06 Alt Freq Source Select 0 1 00 07 Mina Alt Com 1 0 00 12 Max Frequency 60 Hz 60 Hz 00 14 Acceleration time 3 5 4 0 sec 3 5 4 0 sec 00 15 Deceleration time 2 0 sec 2 0 sec 02 00 Motor rated current 3 5A P750 2 4A P550 02 01 Motor protect Current 6 8A P750 4 8A P550 05 02 Gate Open Low Speed 15 15 05 03 Gate Close High Speed 35 35 05 04 Gate Close Low Speed 15 15 ...

Page 10: ...P750LV2 1 industrial gate motor manual 10 6 Set up limit switch ...

Page 11: ...tem is basically standard motor set on the chain drive base How to mounting chain drive motor a Set the motor height The chain base is adjustable Chain slave idle sprocket bottom line is about 10 to 20mm above the bottom line of gate bottom rail b Every 1M need one chain supporter ...

Page 12: ...pened and closed DO NOT TURN THEBOLT MORE THAN ONE TURN OTHERWISE OIL COME OUT 4 After the gate was pushed to the required position fit the spanner onto the manual release blots clockwise turn and make the bolts tight otherwise maybe cause oil leaking B What to do if power is reconnected 1 Make sure the switch circuit breaker is still OFF 2 Fit the spanner onto the bolt nicely and clockwise turn t...

Page 13: ...e for any special indirect incidental or consequent damages of any kind or nature Equipment manufactured and installed by it to be free from defects in material and workmanship for Digiway will repair or replace at its option any product or part which it determines to contain defective material and workmanship Defective parts must be returned to Digiway for repair or replacement Costs associated w...