1.OPN open push button 
2. CLS close push button 
3. PED pedestrian open push button 
4. STP stop push button 
5. OSC open/stop/close push button 
6. PEB photo electrical beams 
7. Gate status display, open green, close red  
8. Mode selection DIP switch 
9. Motor protect fuse 5A and Transformer fuse 0.5A 
10. Main inputs 240VAC. 
11. Motor power input/inverter COM. input 
12. Motor2 open and close outputs 
13. Motor1 open and close outputs  
14. Lock output 
15. Motor2 limit switches  
16. Motor1 limit switches  
17. Limit switch input 12VD/+12VDC @300MA output for the sensor  
18. Control inputs 
19. Set1 and Set2 DIP switch 

 

2.2 Control inputs 

 
2.2.1 Open (OPN) input & OPN push button 
The OPN inputs are Push Button OPN and Terminal OPN input. Push OPN button and activating 
(connect OPN terminal to the +12V) the OPN input will start to open the gate. When gate opened, 
if OPN is keep activating, the gate will stay open. This is mostly controlled by access control 
system. 

 

2.2.2 Pedestrian Access (PED) input and Pedestrian (PED) push button 
The pedestrian input partly opens the gate leaf driven by motor1 in the case of single speed mode, 
or partly opens gate in the case of sliding gate mode.  How far the gate will open depending on the 
Pedestrian Open Time, this can be changed by user. If P.E input is activated during the gate is 
closing, the gate will reopen for another Pedestrian Open Time. P.E Close setting and Auto Close 
setting will also apply to pedestrian cycle. 
 
2.2.3 Close Terminals input (CLS) and Close (CLS) Push button 
 
The CLS terminals input is used to close the gate. Push button on control board is mainly used to 
test when finished the installation. Pushing it will cause gate to close if the gate in the opened 
position or in the opening cycle. If gate is in the closed or closing, the gate situation is not change. 
 
2.2.4 STP stops input and stop button 
 
STP input and STP button is used for stop the gate and settings 
 
2.2.5 OSC (open/stop/close) input 
 
OSC input and OSC button is used for manual operation. Push to open the gate, push again stop 
gate, another push closes the gate.  
 
2.2.6 Photoelectric safety beam (PE) input (N/C type) 
 
If the P.E input is activated while gate is closing, the controller will stop the gate or reopen the 
gate depending on the DIP setting. If the gate in the opened position and P.E beam is activated, the 
gate will stay in opened 

CONTROL INPUIT AND BUTTON 

 

Summary of Contents for P750L

Page 1: ...P750LV2 1 industrial gate motor manual 1 P750L Sliding Gate Motor Version V2 x INSTRUCTION MANUAL IMPORTANT SAFETY WARNING ...

Page 2: ...ON Additional safety device MUST be fitted such as Photo Electric Beam Loop Detectors ATTENTION Before do the manual release the mains power switch must be off even there is no power ATTENTION Before power on the manual release MUST engaged ATTENTION Gate opened stopper and closed gate stopper MUST be installed Contains 1 General description 3 2 Specifications 3 3 Control Board Layout 4 4 DIP swit...

Page 3: ...V2 1 industrial gate motor manual 3 Fig 1 1 AC6 Control Board 2 Mounting Plate 3 Terminals 4 Limit switch 5 Manual Release 6 Transformer 7 Inverter VSD 8 EMC filter 9 Electric motor 10 Gearbox GENERAL LAYOUT ...

Page 4: ...1 5mm thickness has remove door P750 and plenty of room for the access control accessories including din rail mounting 50VA transformer 12V 24v 2A can directly drive magnetic lock warning lights etc Technical Specifications Power supply 230 240V AC at 10A Output voltage 230V AC three phase via inverter Max 0 75KW or 1 5KW Motor rate Three phase two poles 0 75KW Gate type Track or cantilever Drive ...

Page 5: ...en by motor1 in the case of single speed mode or partly opens gate in the case of sliding gate mode How far the gate will open depending on the Pedestrian Open Time this can be changed by user If P E input is activated during the gate is closing the gate will reopen for another Pedestrian Open Time P E Close setting and Auto Close setting will also apply to pedestrian cycle 2 2 3 Close Terminals i...

Page 6: ...is ON the PE beam will work on the open cycle and close cycle DIP6 is off the PE beam will work only in close cycle 2 3 6 NOLS DIP7 ON N O limit OFF N C limit DIP7 is ON the limit inputs change to N O and DIP7 is off the limit inputs are N C 2 3 8 Security close DIP8 ON SEC CLS OFF NO SEC CLS DIP8 is on and P E input is active while the gate is opening if the PE clear the gate controller stops gat...

Page 7: ...ull close run time setting Pedestrian running time Push and hold on PED for the pedestrian open run time setting Sync delay time Motor2 delay time Push and hold on STP for the sync delay time setting Auto close time set Push and hold on OSC for the auto close time setting PE close time set Push and hold on PEB for the PE close time setting 2 5 2 SET2 time setting Turn SET1 off and SET2 on Warn tim...

Page 8: ...which plugs into the control board the control board will control light which will illuminate the driveway etc The light will automatically turn off after preset time customer programmable If DIP4 is set to ON the M2 output will change to light output 4 Audio warn output On Board buzzer can give warn for diagnose Additional buzzer or relay module which plugs into the control board the control boar...

Page 9: ...Main Freq Source 1 0 00 06 Alt Freq Source Select 0 1 00 07 Mina Alt Com 1 0 00 12 Max Frequency 60 Hz 60 Hz 00 14 Acceleration time 3 5 4 0 sec 3 5 4 0 sec 00 15 Deceleration time 2 0 sec 2 0 sec 02 00 Motor rated current 3 5A P750 2 4A P550 02 01 Motor protect Current 6 8A P750 4 8A P550 05 02 Gate Open Low Speed 15 15 05 03 Gate Close High Speed 35 35 05 04 Gate Close Low Speed 15 15 ...

Page 10: ...P750LV2 1 industrial gate motor manual 10 6 Set up limit switch ...

Page 11: ...tem is basically standard motor set on the chain drive base How to mounting chain drive motor a Set the motor height The chain base is adjustable Chain slave idle sprocket bottom line is about 10 to 20mm above the bottom line of gate bottom rail b Every 1M need one chain supporter ...

Page 12: ...pened and closed DO NOT TURN THEBOLT MORE THAN ONE TURN OTHERWISE OIL COME OUT 4 After the gate was pushed to the required position fit the spanner onto the manual release blots clockwise turn and make the bolts tight otherwise maybe cause oil leaking B What to do if power is reconnected 1 Make sure the switch circuit breaker is still OFF 2 Fit the spanner onto the bolt nicely and clockwise turn t...

Page 13: ...e for any special indirect incidental or consequent damages of any kind or nature Equipment manufactured and installed by it to be free from defects in material and workmanship for Digiway will repair or replace at its option any product or part which it determines to contain defective material and workmanship Defective parts must be returned to Digiway for repair or replacement Costs associated w...

Reviews: