background image

P750LV2.1 industrial gate motor manual  

 

 

2.5 Timers setting  

 

Push Buttons functions 

Button 

SET1

---ON  

SET2 

--- ON 

Set1 and Set2 both off

---Running  

OPN 

Open cycle time set 

Warning time set 

Open gate 

CLS 

Close cycle time set 

Lock time set 

Close gate 

PED  

PED cycle time set 

LGT time set 

Partial open gate 

STP 

Sync motor time set  

Motor stop time set 

Stop gate 

OSC 

Auto close time set 

Two T1 --spare 

Open-Stop-Close gate 

PEB 

PE close time set 

Two T2 -- Spare 

PE. Input (simulated) 

 

2.5.1 Set1 time settings 

Turn SET1 on(Set2 off), red and green LED flashes a little fast alternatively. 

 
Open cycle time 

Push and hold on OPN for the full open run time setting  

 

Close cycle time 

Push and hold on CLS for the full close-run time setting

 

 
Pedestrian running time 

Push and hold on PED for the pedestrian open run time setting 
 

 

Sync delay time (Motor2 delay time) 

Push and hold on STP for the sync delay time setting. 

  
Auto close time set 

 

Push and hold on OSC for the auto close time setting.  

 
PE close time set 

Push and hold on PEB for the PE close time setting.  

 

2.5.2 SET2 time setting 
 

Turn SET1 off and SET2 on 

 
Warn time set

 

Push and hold on OPN for Warning time setting.  
 

Lock pulse time set

 

Push and hold on CLS for the lock pulse time setting 
 

LGT time  

 

Push and hold on PED for the PE trig close time setting 
 

Motor Stop time 

Push and hold on STP for the motor stop time setting 

Two-T1 time1 (spare for late use)

 

Push and hold on OSC for the Two-T1 time setting 

 
Two-T2 time2 (spare for late use

 

Push and hold on PEB for the Two-T2 time setting.  
 
Turn SET2 OFF. The gate controller will back to working mode. 

Summary of Contents for P750L

Page 1: ...P750LV2 1 industrial gate motor manual 1 P750L Sliding Gate Motor Version V2 x INSTRUCTION MANUAL IMPORTANT SAFETY WARNING ...

Page 2: ...ON Additional safety device MUST be fitted such as Photo Electric Beam Loop Detectors ATTENTION Before do the manual release the mains power switch must be off even there is no power ATTENTION Before power on the manual release MUST engaged ATTENTION Gate opened stopper and closed gate stopper MUST be installed Contains 1 General description 3 2 Specifications 3 3 Control Board Layout 4 4 DIP swit...

Page 3: ...V2 1 industrial gate motor manual 3 Fig 1 1 AC6 Control Board 2 Mounting Plate 3 Terminals 4 Limit switch 5 Manual Release 6 Transformer 7 Inverter VSD 8 EMC filter 9 Electric motor 10 Gearbox GENERAL LAYOUT ...

Page 4: ...1 5mm thickness has remove door P750 and plenty of room for the access control accessories including din rail mounting 50VA transformer 12V 24v 2A can directly drive magnetic lock warning lights etc Technical Specifications Power supply 230 240V AC at 10A Output voltage 230V AC three phase via inverter Max 0 75KW or 1 5KW Motor rate Three phase two poles 0 75KW Gate type Track or cantilever Drive ...

Page 5: ...en by motor1 in the case of single speed mode or partly opens gate in the case of sliding gate mode How far the gate will open depending on the Pedestrian Open Time this can be changed by user If P E input is activated during the gate is closing the gate will reopen for another Pedestrian Open Time P E Close setting and Auto Close setting will also apply to pedestrian cycle 2 2 3 Close Terminals i...

Page 6: ...is ON the PE beam will work on the open cycle and close cycle DIP6 is off the PE beam will work only in close cycle 2 3 6 NOLS DIP7 ON N O limit OFF N C limit DIP7 is ON the limit inputs change to N O and DIP7 is off the limit inputs are N C 2 3 8 Security close DIP8 ON SEC CLS OFF NO SEC CLS DIP8 is on and P E input is active while the gate is opening if the PE clear the gate controller stops gat...

Page 7: ...ull close run time setting Pedestrian running time Push and hold on PED for the pedestrian open run time setting Sync delay time Motor2 delay time Push and hold on STP for the sync delay time setting Auto close time set Push and hold on OSC for the auto close time setting PE close time set Push and hold on PEB for the PE close time setting 2 5 2 SET2 time setting Turn SET1 off and SET2 on Warn tim...

Page 8: ...which plugs into the control board the control board will control light which will illuminate the driveway etc The light will automatically turn off after preset time customer programmable If DIP4 is set to ON the M2 output will change to light output 4 Audio warn output On Board buzzer can give warn for diagnose Additional buzzer or relay module which plugs into the control board the control boar...

Page 9: ...Main Freq Source 1 0 00 06 Alt Freq Source Select 0 1 00 07 Mina Alt Com 1 0 00 12 Max Frequency 60 Hz 60 Hz 00 14 Acceleration time 3 5 4 0 sec 3 5 4 0 sec 00 15 Deceleration time 2 0 sec 2 0 sec 02 00 Motor rated current 3 5A P750 2 4A P550 02 01 Motor protect Current 6 8A P750 4 8A P550 05 02 Gate Open Low Speed 15 15 05 03 Gate Close High Speed 35 35 05 04 Gate Close Low Speed 15 15 ...

Page 10: ...P750LV2 1 industrial gate motor manual 10 6 Set up limit switch ...

Page 11: ...tem is basically standard motor set on the chain drive base How to mounting chain drive motor a Set the motor height The chain base is adjustable Chain slave idle sprocket bottom line is about 10 to 20mm above the bottom line of gate bottom rail b Every 1M need one chain supporter ...

Page 12: ...pened and closed DO NOT TURN THEBOLT MORE THAN ONE TURN OTHERWISE OIL COME OUT 4 After the gate was pushed to the required position fit the spanner onto the manual release blots clockwise turn and make the bolts tight otherwise maybe cause oil leaking B What to do if power is reconnected 1 Make sure the switch circuit breaker is still OFF 2 Fit the spanner onto the bolt nicely and clockwise turn t...

Page 13: ...e for any special indirect incidental or consequent damages of any kind or nature Equipment manufactured and installed by it to be free from defects in material and workmanship for Digiway will repair or replace at its option any product or part which it determines to contain defective material and workmanship Defective parts must be returned to Digiway for repair or replacement Costs associated w...

Reviews: