11
5.7
Note: The Square Deal ships with the Primer System size installed for the cartridge ordered. The
alternate small or large Primer Assembly is shipped in the Accessory box. Refer to Section 8.3 on the
Primer Conversion Procedures for changing primer size.
5.8
Install the Primer Early Warning System
5.8.1
The Primer Early Warning system emits a “beeping” sound when the Primer Magazine is down to the last
three or four primers.
5.8.2
Simply push the Primer Early Warning System down over the Primer Magazine Shield Knurled Cap until it
stops.
5.8.3
WARNING! Do not put primers in the Magazine Tube until you have read this entire manual.
5.8.4
Install the Primer Magazine Follower Rod as shown below. You can store the plastic Primer Follower Rod
in the Magazine Tube when there are no primers in the Magazine Tube by putting it under the Operating
Lever to stop the alarm from sounding when it is not being used.
5.9
Your assembly is complete. Cycle the Operating Handle making a full stroke down and up again and push
fully to the rear to the priming position. The Shellplate should index clockwise. The Primer Slide should
move back and forth and the Primer Punch will project up through the hole in the Shellplate.
Store Rod as
shown to
disable the
audio alert
when no
primers are
present
Press EWS down over the Knurled Nut
Install Follower
Rod
Summary of Contents for Square Deal B
Page 50: ...50 13 DILLON PRECISION Square Deal B EXPLODED VIEWS AND PARTS IDENTIFIER 13 1 Main Assembly ...
Page 51: ...51 13 2 Frame and Lower Assembly Index Assembly Index Assembly installed in Frame Index Pawl ...
Page 52: ...52 13 3 Typical Toolhead Assembly 45ACP Shown ...
Page 53: ...53 13 4 Automatic Primer Assembly ...
Page 55: ...55 13 6 Primer Early Warning System ...