37
Thread the Crimp Adjustment Plug into Station #4 of the Toolhead four turns down as a starting point.
Reinstall the Powder Measure by sliding the Powder Measure down over the Powder Die and securing it
with the Powder Measure Clamp/Screw. Secure the Failsafe Rod to the Lock Link Assembly with Spring
Clip.
Install three numbered Locator Pins from the Conversion Kit
Slide the Powder Measure down
over the Powder Die and secure
it with the Powder Measure
Clamp-Screw
Reconnect the Failsafe Rod to
the Powder Measure and secure
it with the Spring Clip
Thread the Crimp Adjustment Plug into Station #4 using
the Bench Wrench or a 3/4” Wrench four turns down as a
starting point—further adjustment is required
Install three
numbered Locator
Pins