❖Wiring
Red
R(200V 50/60Hz)
PC-A
Power cable
White
S(200V 50/60Hz)
0.75mm
2
Black
T(200V 50/60Hz)
Not wiring when single phase
Green/Yellow
E(Earth)
1
PC-B
Signal cable
2
0.5mm
2
Option
3
4
5
6
Wire #
1:2
1A at AC 250V or less
7
3:4
1A at DC 30V or less
5:6
8
24V GND
Example for circuit
7 8
Wire # 7:8 9:10 11:12
S5:S6
0V EMG
100V
5V
24V
R
CPU
7,9,11 ,S5
5V GND
8,10,12, S6
9
Feed input
Wire #
1A at AC 250V or less
10
24V GND
S1:S2
1A at DC 30V or less
11
Release input
S3:S4
12
24V GND
S1
S2
S3
PC-C
S4
0.5mm
2
Option
S5
S6
Blown:24V GND
Need to short, if not
using.
Black:Emergency stop
DANGER
To cover each cable which is not using connection.
CAUTION
Yellow:Press cont.
processing
Need to short, if not
using.
Need to short the circuit of press processing select(S5, S6), if you don't use the
circuit.
To the stop continuous
on the press circuit
Work shortage sensor
output
To the stop continuous
on the press circuit
Continuous stop signal
output
To the stop continuous
on the press circuit
Red:Emergency stop
To Emergency stop circuit
Input stop
of Feeder
Press cam signal
CAUTION
You can select which 3 phase or single phase. If it's single phase, you don't have to connect the black wire.
Press cam signal
White:Emergency stop
To Emergency stop circuit
DANGER
Connect to the primary side
Emergency and press
processing select
Green:Emergency stop
Drive stop signal output
3