OPU-1
UNIVERSAL POWER-LINE CARRIER SYSTEM TYPE OPU-1
GENERAL DESCRIPTION - Rev 7 (May 2019)
19/67
2.1
BASIC MODULES FOR TERMINALS OF 20 AND 40 W
FAPU
POWER SUPPLY
This module contains the DC/DC converter that generates the internal
power-supply voltages from the input voltage, as well as a filter at the input to
suppress disturbance caused by fast transient bursts.
The module also contains the power-supply alarm external signalling relay.
The type of module depends on the nominal input voltage. The following types
are available:
FAPU.02
Input voltage of 48 V
DC
.
FAPU.10
Input voltage of 110 V
DC.
FAPU.10/20
Input voltage from 110 to 220 V
DC
and V
AC.
If power-supply redundance is necessary, the OPU-1 terminal must be
equipped with two power-supply modules.
The power supply is protected against polarity inversion.
MOPU.1X MANAGEMENT & ANALOG SIGNAL PROCESSING UNIT
On the one hand, it contains the central management unit that is made up of:
LAN interface (10/100Base-Tx), loop control, a decoder capable of processing
according to IRIG-B standard, a web server, an SNMP agent and the
associated MIB, and service channel.
On the other hand, for processing the analog signals, it contains a central
processing unit that is made up of: the circuits for the mixing of the signals to be
transmitted, modulation and demodulation circuits, synchronization circuits, digital
signal filtering, signal-to-noise ratio measurement and automatic gain control
(AGC) circuits.
It also contains the whole-band service-telephony circuits, which are operational
only when the IOPU module is not installed in the equipment.
The type of module depends on whether the terminal is working with one or
two analog channels in this way:
MOPU.10
One analog channel (CH1).
MOPU.11
Two analog channels (CH1 and CH2).