OPU-1
UNIVERSAL POWER-LINE CARRIER SYSTEM TYPE OPU-1
GENERAL DESCRIPTION - Rev 7 (May 2019)
57/67
The terminal has three alarm signalling relays
to which an alarm or combination of alarms
can be assigned from the Management
System
Power-supply alarm external signalling
Type
By relay. Changeover contact. Contact rating:
1 A/250 V
AC
, see FIGURE 14 for V
DC
Number of relays
One per power supply
State in normal operation
conditions
Energized
(N.O.
and
C
contacts
short-circuited)
Alarm external signalling
Type
By relay. Changeover contact. Contact rating:
1 A/250 V
AC
, see FIGURE 14 for V
DC
Number of relays
3 relays whose alarm condition can be
programmed by the user.
Any alarm situation that occurs in the terminal,
as well as in the collateral, is shown on the
front plate of the terminal by means of the
GENERAL ALARM LED and REMOTE
ALARM LED, respectively
State in normal operation
conditions
Energized
(N.O.
and
C
contacts
short-circuited)
Timing for relay activation
Programmable between 0 and 60 s
Test elements
➢
Analog channel:
❖
Possibility of carrying out HF and
audio-frequency test loops.
➢
Digital channel:
❖
Data loop in local and remote terminals.
❖
High-frequency loop (isolated terminal).
❖
Displaying of the XMT and RCV signal
space constellation by means of
oscilloscope (QAM).