E
N
G
L
IS
H
28
INSTALLATION LAYOUT
PREPARATORY STEPS
The new series of actuadors MOOV, has been devised to serve gates up to 200 Kg with leaf up to 2,5 meters wide (look at the table
technical data). Before proceeding with the installation, please make sure that your gate opens and closes freely, and that:
• Hinges and pins are in optimum condition and properly greased.
• No obstacles are within the moving area.
• There is no friction with the ground or between the leaves.
• Your gate shall be equipped with central
and side
stops, which are fundamental for the good system operation.
Actuator
cable 4 x 1 mm
2
Blinker
cable 2 x 1,5 mm
2
Aerial
cable RG-58
Key or digital selector
cable 2 x 1 mm
2
Safety ribbon (EN 12978)
-
Internal photocells
cable 4 x 1 mm
2
(RX)
cable 2 x 1 mm
2
(TX)
External photocells
cable 4 x 1 mm
2
(RX)
cable 2 x 1 mm
2
(TX)
Control unit
cable 3 x 1,5 mm
2