Page 1: ...680000R03 In keeping with our policy of continuous product development we reserve the right to make changes without notice 2012 Dimplex North America Limited Dimplex North America Limited 1367 Industr...

Page 2: ...d Replacement 8 Heater Element Replacement 8 Blower Motor Blower Replacement 9 Temperature Limit Switch Replacement 9 Remote Control Receiver Replacement 9 Input Voltage Changing 10 REWIRE UNIT FROM 2...

Page 3: ...st obstacles including walls It is supplied with one of 243 independent frequencies to prevent interference with other units The frequency designation is indicated on the back of the remote control Fi...

Page 4: ...e the log grate retaining screws and remove the log grate 3 Pull the rear edge of the log set forward by grasping the ember bed by the sides handle the log set only by the ember bed and not the logs a...

Page 5: ...5 1 2 10 6 7 3 4 5 11 8 12 13 9 14 Exploded Parts Diagram...

Page 6: ...1580100RP also 11 Heating Element 2200460100RP 12 Cutout 2300200100RP 2300200800RP 2300200100RP 2300200800RP 13 Mesh Curtain 8800240103RP 14 Voltage Selector Switch N A N A Not Available N A Not Avail...

Page 7: ...7 Wiring Diagram Mod 0 B Mod C E...

Page 8: ...ogs and pulling firmly until the rear tab pops out from under the back ledge then lift out 4 Remove the retaining screws on the light assembly retaining plate and remove being careful not to damage an...

Page 9: ...d rubber channel has been cut use the chan nel that was supplied with the replacement motor blower Slide the channel onto the edge of the partially reflective glass and push the other side of the part...

Page 10: ...their original mounting locations NOTE To replace the log set insert the front edge of the log set and pushing back down until the rear tab snaps under the back ledge and the logs are resting against...

Page 11: ...e neutral wire from the power supply Connect the green ground wire to the ground wire from the power supply 4 Once the wiring has been configured for the proper sup ply voltage replace wire bundle ins...

Page 12: ...ff Switch Defective Heater Switch Replace Heater Switch Defective Remote Control Receiver If ap plicable Replace Remote Control Receiver Fireplace does not turn on with remote control if applicable Im...

Page 13: ...turned on The heater is burning off any dust accumulated during manufacturing or operation Defective heater assembly Replace heater assembly Heater fan turns on but heater lacks heat Improper operati...