background image

 

2

 

OPERATION

 

 
To access the controls, swing down the front cover panel located on the lower front of 
the Fireplace (refer to diagram below). 

 

 

 

A.

 

MAIN ON/OFF SWITCH 

 

The on/off switch supplies power to all unit functions (heat/flame) 

 

 

 

B. HEATER ON/OFF SWITCH  

The HEATER ON/OFF SWITCH supplies power to the heater fan and the heater 
element. 

 

 

 

C. HEATER THERMOSTAT CONTROL 

To adjust the temperature to your individual requirements, turn the thermostat control 
clockwise all the way to turn on the heater.  When the room reached the desired 
temperature, turn the thermostat knob counter clockwise until you hear a click.  Leave in 
this position to maintain the room temperature at this setting.  For additional heat, turn 
clockwise until you hear the click again and the heater will turn on.  To turn the heater 
off, switch the HEATER ON/OFF SWITCH to the OFF position. 

 

 

NOTE:

 When the heater is switched ON, the heater fan will operate.  The heater 

element may or may not be on, depending on the thermostat control setting (SEE 
“HEATER THERMOSTAT CONTROL”). 

 
 
 

 

 

 

 

 

 

 

 
 
 

RESETTING THE TEMPERATURE CUTOFF SWITCH 

This unit is equipped with a thermostat, which controls the temperature of the room.  It 
does this by turning the heater on and off.  The heater is protected with a safety device 
to prevent overheating.  Should the heater overheat, an automatic cut out will turn the 
heater off and it will not come back on without being reset.  It can be reset by switching 
the ON/OFF SWITCH to OFF and waiting 5 minutes before switching the unit back on. 

 

CAUTION 

If you need to continuously reset the heater, unplug the unit and call Dimplex North 
America Limited at 1-800-668-6663. 
 
 
 
 

A

COVER PANEL 

Summary of Contents for 6901860100

Page 1: ...PARTS SERVICE MANUAL FOR THE COMPACT FIREPLACE...

Page 2: ...M PAGE 5 LIGHT BULB REPLACEMENT PAGE 6 MAIN ON OFF SWITCH REPLACEMENT PAGE 7 HEAT ON OFF SWITCH REPLACEMENT PAGE 8 THERMOSTAT CONTROL REPLACEMENT PAGE 9 FLAME MOTOR FLAME ROD REPLACEMENT PAGE 10 HEATE...

Page 3: ...ear the click again and the heater will turn on To turn the heater off switch the HEATER ON OFF SWITCH to the OFF position NOTE When the heater is switched ON the heater fan will operate The heater el...

Page 4: ...3 1 11 3 4 8 6 14 6 7 9 2 12 5 15 10 13...

Page 5: ...300150100RP 6 ON OFF SWITCH 2800070200RP 2800070200RP 7 CAPACITOR 3200030100RP 3200030100RP 8 TERMINAL BLOCK 4000070100RP 4000070100RP 9 CORD SET 4100090104RP 4100090104RP 10 REFLECTOR ASSEMBLY 590034...

Page 6: ...CUTOUT 2300270100RP 5 THERMOSTAT 2300150100RP 6 ON OFF SWITCH 2800070200RP 7 CAPACITOR 3200030100RP 8 TERMINAL BLOCK 4000070100RP 9 CORD SET 4100090104RP 10 REFLECTOR ASSEMBLY 5900340100RP 11 MIRROR 5...

Page 7: ...6 WIRING DIAGRAM...

Page 8: ...od idea to replace all of the light bulbs at one time if they are close to the end of their rated life Group replacement will reduce the number of times you need to open the unit to replace the light...

Page 9: ...t to the mantel 3 Carefully remove the Compact Fireplace from the mantel holding onto the front glass so that it does not move WARNING The front glass is held to the Compact Fireplace with double side...

Page 10: ...mantel holding onto the front glass so that it does not move WARNING The front glass is held to the Compact Fireplace with double sided tape and could come apart when separated from the mantel 4 Remo...

Page 11: ...ass so that it does not move WARNING The front glass is held to the Compact Fireplace with double sided tape and could come apart when separated from the mantel 4 Remove the front glass and set aside...

Page 12: ...lace from the mantel holding onto the front glass so that it does not move WARNING The front glass is held to the Compact Fireplace with double sided tape and could come apart when separated from the...

Page 13: ...with double sided tape and could come apart when separated from the mantel 4 Remove the front glass and set aside 5 Remove the 2 screws on the top panel that are closest to the front of the unit 6 Rem...

Page 14: ...ure it to the mantel 3 Carefully remove the Compact Fireplace from the mantel holding onto the front glass so that it does not move WARNING The front glass is held to the Compact Fireplace with double...

Page 15: ...e 2 screws from the light access cover that secure it to the mantel 3 Carefully remove the Compact Fireplace from the mantel holding onto the front glass so that it does not move WARNING The front gla...

Reviews: