background image

4             www.dimplex.com

MAINTENANCE

WARNING: 

Disconnect power before attempting any 

maintenance or cleaning to reduce the risk of fire, 

electric shock or damage to persons.

Partially Reflective Glass Cleaning

The Partially Reflective Glass is cleaned in the factory 

during the assembly operation. During shipment, 

installation, handling, etc., the Partially Reflective Glass 

may collect dust particles; these can be removed by 

dusting lightly with a clean dry cloth.

To remove fingerprints or other marks, the Partially 

Reflective Glass can be cleaned with a damp cloth. The 

Partially Reflective Glass should be completely dried with a 

lint free cloth to prevent water spots. To prevent scratching, 

do not use abrasive cleaners.

Fireplace Surface Cleaning

Use only a damp cloth to clean painted surfaces of the 

fireplace. Do not use abrasive cleaners.

Servicing

Except for installation and cleaning described in this 

manual, an authorized service representative should 

perform any other servicing.

Figure 2

A

D

B

C

E

G

H

F

•  Indicated by the second digit on the Floating Display™ 

changing to show: “H” (high), and “L” (low).

H .   Sleep Timer

The Sleep Timer can be set to automatically shut off the 

fireplace after a preset time (from 30 minutes to 8 hours).
→ To set the timer press the timer button on the remote, 

repeatedly, until the desired time is displayed.

• 

The On Screen Display will display the different times as 

it is adjusted. Once the timer has begun, pressing the 

 

button will display the time remaining before the unit 

turns Off.

!

 

NOTE: 

The Sleep Timer can be cancelled at any time 

by pressing the 

 

button repeatedly until the sleep timer 

displays nothing.

Resetting the Temperature Cutoff Switch

Should the heater overheat, an automatic cut out will turn 

the heater off and it will not come back on without being 

reset.  It can be reset by unplugging the unit and waiting 5 

minutes before plugging the unit back in.

 CAUTION:  

If you need to continuously reset the heater, 

unplug the unit and call technical support at 1-888-346-

7539.

Remote Control Battery Replacement

To replace the battery:
1.  Slide battery cover open on the remote control. Cor-

rectly install one 3 Volt (CR2032 [longer life] or CR2025) 

battery in the battery holder.

2.  Close the battery cover.

Battery must be recycled or disposed of properly. 

Check with your Local Authority or Retailer for recy-

cling advice in your area

Summary of Contents for 6908492100

Page 1: ...rth America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N3H 4W3 1 888 346 7539 www dimplex com REV PCN DATE 00 13 JAN 16 01 3 MAY 16 IMPORTANT SAFETY INFORMATION Alw...

Page 2: ...not carefully followed will expose the user to the risk of fire serious injury or death Operation 3 Maintenance 4 Exploded Parts Diagram 5 Replacement Parts List 5 Wiring Diagram 6 Partially Reflectiv...

Page 3: ...heme of the cycle is a prism where the unit cycles through a variety of colors Pressing the button stops the cycling and holds the unit on the preferred color indicated by a solid circle When the unit...

Page 4: ...w H high and L low H Sleep Timer The Sleep Timer can be set to automatically shut off the fireplace after a preset time from 30 minutes to 8 hours To set the timer press the timer button on the remote...

Page 5: ...rdware Kit 9600350100RP 8 Mounting Bracket 1017130259RP 9 Display Control Board 3001430200RP 10 Switchboard 3001520100RP 11 Relay Board 3001440200RP 12 AC DC Adapter 2100250100RP 13 Remote Control 670...

Page 6: ...6 www dimplex com WIRING DIAGRAM CN3 CN3 CN4 CN6 CN6 CN4...

Page 7: ...remaining 9 screws from the end panel 7 Remove the end panel being careful not to add any strain to the wires connecting to the switchboard Fig ure 6 8 Gently guide the partially reflective glass out...

Page 8: ...the flanges on the end panel are positioned on the interior of the outside panel of the fire place POWER CORD REPLACEMENT Tools Required Phillips head screwdriver Needle nose pliers Flat Head Screwdr...

Page 9: ...ront panel the 3 screws along the back of the unit Figure 7 and the 5 screws on the left hand panel 11 Reconnect the wires according to their original configu ration 12 Re assemble the remainder of th...

Page 10: ...r cavity and remove all of the wiring connections noting their original location 13 Connect the wiring to the new heater assembly and re place the four screws to secure the assembly to the unit 14 Re...

Page 11: ...t on a flat working surface NOTE If necessary lay a protective barrier between the unit and your work surface i e cloth cardboard thick plastic to avoid scratching your work surface 5 On the right end...

Page 12: ...d scratching your work surface 5 On the right end with the switchboard remove the ten screws around the outside of the end panel Figure 5 6 Lay unit on its back and remove the remaining 9 screws from...

Page 13: ...er adapter 2100250100RP Fireplace does not turn on in Remote Mode Improper operation Refer to Operation Section Remote Control not working Install new battery into the Remote Control Replace Remote Co...

Page 14: ...ly Replace Heater Assembly 2203610400RP Heater emits an odor Normal Operation Normal operation is when the heater emits an odor for a brief period after the heater is initially turned on The heater is...

Reviews: