Flicker Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2000220100RP

Heater Assembly (with Cutout) . . . . . . . . . . . . . . . . . .

2203610100RP

Thermostat with Knob

 . . . . . . . . . . . . . . . . . . . . . . . . .

2600090100RP

3 Position Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

2800071100RP

Heater On/Off Switch. . . . . . . . . . . . . . . . . . . . . . . . . . 

2800070700RP

Cord Set

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4100090203RP

Flicker Rod  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5902620100RP

Partially Reflective Panel . . . . . . . . . . . . . . . . . . . . . . .

5902580100RP

Front Glass

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5902570100RP

Remote Control

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

3000370500RP

Remote Control Reciever. . . . . . . . . . . . . . . . . . . . . . . . 

3000380200RP

LED Driver Board  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

3001170100RP

LED Light Assembly (2 LED's)  . . . . . . . . . . . . . . . . . .

3001180100RP

LED Light Assembly (3 LED's)  . . . . . . . . . . . . . . . . . .

3001180200RP

Felt Feet Pads (Set of 4) . . . . . . . . . . . . . . . . . . . . . . .

8600140101RP

Log Set Assembly

 . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0478550100RP

Glass Media

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

0441480100RP

For service questions, please call Dimplex at 1-888-346-7539.
For sales inquiries, please call Sylvane at 1-800-934-9194 or visit
sylvane.com.

Summary of Contents for 6908890459

Page 1: ...e this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage To view the full line of Dimplex products please visit www dimplex com For service questions please call Dimplex at 1 888 346 7539 For sales inquiries please call Sylvane at 1 800 934 9194 or visit sylvane com ...

Page 2: ...ugh to emphasize CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose the user to the risk of fire serious injury or death Welcome Congratulations 3 IMPORTANT INSTRUCTIONS 4 Fireplace Installation 7 Operation 9 Maintenance 11 Warranty 12 Replacement Parts 14 ...

Page 3: ...re hazard and will void the warranty Please record your model and serial numbers below for future reference model and serial numbers can be found on the Model and Serial Number Label NO NEED TO RETURN TO THE STORE Questions with operation or assembly Require Parts Information Product Under Manufacturer s Warranty Contact us at www dimplex com customer_support For Troubleshooting and Technical Supp...

Page 4: ...oned or if it has been dropped or damaged in any manner Contact technical service at 1 888 346 7539 IMPORTANT INSTRUCTIONS Do not use outdoors This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate this heater where it may fall into a bathtub or other water container Do not run cord under carpeting Do not cover cord with throw rugs runners or the l...

Page 5: ...er outlet Do not change the plug in any way Always plug heaters directly into a wall outlet receptacle Never use with an extension cord or relocatable power tap outlet power strip Do not burn wood or other materials in the Compact Fireplace Do not strike the front glass Always use a certified electrician should new circuits or outlets be required Always use properly grounded fused and polarized ou...

Page 6: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or reloc...

Page 7: ...mp 120 Volt alternating current VAC circuit is required A dedicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker trips or fuse blows on a regular basis when the heater is operating Additional appliances on the same circuit may exceed the current rating of the circuit breaker Glass Installation 1 Unpack the firebo...

Page 8: ...rew that was removed attach the fire box to the mantel Figure 2 NOTE There are no guide holes provided for the L Brackets in the mantel If not installing the unit into a Dim plex mantel the required opening dimensions of the fireplace are 21 in 540 mm wide x 21 in 550 mm high x 7 in 184 mm deep Figure 3 The firebox is to be installed from the front of the mantel and inserted so that the flanges ar...

Page 9: ...continue running even when the heater is not when the Heater Switch is in the ON position C Heater Thermostat Control To adjust the temperature to your individual requirements turn the thermostat control clockwise all the way to turn on the heater When the room reaches the desired temperature turn the thermostat knob counter clock wise until you hear a click Leave in this position to maintain the ...

Page 10: ...emote control pull the plastic insulator strip out from between the remote casing and battery cover Figure 5 Remote Control Initialization Reprogram In the event that your remote control ceases to operate your fireplace follow these steps to reinitialize the remote control and the remote control receiver in the fireplace 1 Place the 3 Position Switch Figure 4A in the OFF O position 2 Wait a minimu...

Page 11: ...ngerprints or other marks the front glass panel can be cleaned with a damp cloth The front glass panel should be completely dried with a lint free cloth to prevent water spots To Operation Battery Replacement To replace the battery 1 Slide battery cover open on the remote control Figure 4 2 Correctly install one 12 Volt A23 battery in the battery holder prevent scratching do not use abrasive clean...

Page 12: ...ve been tested and inspected prior to shipment and subject to the provisions of this warranty Dimplex warrants such products to be free from defects in material and workmanship for a period of 12 months from the date of the first purchase of such product The limited 12 month warranty period also applies to any implied warranties that may exist under applicable law Some jurisdictions do not allow l...

Page 13: ... transportation costs Such costs shall be the purchaser s responsibility What Dimplex and its dealers and service agents are also not responsible for IN NO EVENT WILL DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY WHETHER IN CONTRACT IN TORT OR ON ANY OTHER BASIS FOR ANY INDIRECT SPECIAL PUNITIVE EXEMPLARY CONSEQUENTIAL OR INCIDENTAL LOSS COST OR DAMAGE A...

Page 14: ... Cord Set 4100090203RP Flicker Rod 5902620100RP Partially Reflective Panel 5902580100RP Front Glass 5902570100RP Remote Control 3000370500RP Remote Control Reciever 3000380200RP LED Driver Board 3001170100RP LED Light Assembly 2 LED s 3001180100RP LED Light Assembly 3 LED s 3001180200RP Felt Feet Pads Set of 4 8600140101RP Log Set Assembly 0478550100RP Glass Media 0441480100RP For service question...

Reviews: