background image

Service Manual

Model Number:

DF2000

UL Part Number

690889XXXX

7400690100R00

In keeping with our policy of continuous product development, we reserve the right to make changes without notice.

© 2013 Dimplex North America Limited

Dimplex North America Limited

1367 Industrial Road   Cambridge ON Canada N1R 7G8

1-888-346-7539   www.dimplex.com

REV PCN

DATE

00

-

13-AUG-13

-

IMPORTANT SAFETY INFORMATION

: Always read this manual first before attempting to service this 

fireplace. For your safety, always comply with all warnings and safety instructions contained in this 

manual to prevent personal injury or property damage.

Summary of Contents for 690889XXXX Series

Page 1: ...orth America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1 888 346 7539 www dimplex com REV PCN DATE 00 13 AUG 13 IMPORTANT SAFETY INFORMATION Always read th...

Page 2: ...r to the risk of fire serious injury or death OPERATION 3 MAINTENANCE 4 EXPLODED PARTS DIAGRAM 5 REPLACEMENT PARTS 5 WIRING DIAGRAM 6 3 POSITION SWITCH REPLACEMENT 7 HEATER ON OFF SWITCH REPLACEMENT 7...

Page 3: ...ch has two ON positions marked with I and II The I position is for manual operation In this position the built in remote control is by passed The II position is for operating the unit with the provide...

Page 4: ...lightly with a clean dry cloth To remove fingerprints or other marks the front glass panel can be cleaned with a damp cloth The front glass panel should be completely dried with a lint free cloth to...

Page 5: ...itch 2800070700RP 6 Cord Set 4100090203RP 7 Flicker Rod 5902620100RP 8 Partially Reflective Panel 5902580100RP 9 Front Glass 5902570100RP 10 Remote Control 3000370500RP 11 Remote Control Receiver 3000...

Page 6: ...6 www dimplex com WIRING DIAGRAM Units with glass media Units with log set...

Page 7: ...reverse order as above Figure 3 HEATER ON OFF SWITCH REPLACEMENT Tools Required Phillips Head Screwdriver Flat Head Screwdriver CAUTION If unit was operating prior to servicing allow at least 10 minut...

Page 8: ...ee screws along the back of the unit the two on either side along the top edge and the two at the top of the glass retaining bracket on both sides Figure 3 4 Lay the Compact Fireplace on its back 5 Ge...

Page 9: ...back of the bottom panel and push while twisting to remove 8 Install the new power cord 9 Reassemble in the reverse order as above FLICKER MOTOR FLICKER ROD REPLACEMENT Tools Required Phillips Head Sc...

Page 10: ...edle nose pliers to depress the tab on the mounting standoffs and gently lift the driver board off 11 Properly orient and install the new LED driver board and connect all of the wiring 12 Reassemble i...

Page 11: ...t ive Panel Figure 9 IMPORTANT Only handle the Log Set by the Ember Bed NOTE Log Set fits tightly into firebox some force may be necessary to remove 7 Reassemble in the reverse order as above GLASS ME...

Page 12: ...r operation Refer to Operation Section No incoming voltage from the electrical wall socket Check Fuse Breaker Panel Loose wiring Check wiring connections Defective 3 Position Switch Replace 3 Position...

Page 13: ...ter is initially turned on The heater is burning off any dust accumulated during manufacturing or operation Defective Heater Assembly Replace Heater Assembly Heater fan turns on but heater lacks heat...