8
www.dimplex.com
Fireplace Installation
insert directly on carpet or
similar surfaces which may
restrict air circulation.
CAUTION:
If installing the fire-
place in a carpeted area, place a
one-piece, solid, flat surface under
the fireplace. Ensure that all of the
feet rest securely on this surface.
4. The firebox is to be installed
from the front of the mantel and
inserted so that the flanges are
flush against the front surface of
the mantel.
N
L
LOGSET ASSEMBLY
MEDIA BED RGB LED STRIP
MEDIA BED LED ASSEMBLY
~
120V / 12V
AC / DC
CUTOUT
FLICKER
MOTOR
BLOWER
MOTOR
DISPLAY-CONTROL BOARD
M
+T°
M
ELEMENT
AC/DC
ADAPTER
SWITCHBOARD
RELAY BOARD
THERMISTOR
LOGSET LED ASSEMBLY
LED LIGHT ASSEMBLY
Wiring Diagram
Bathroom Installation
This firebox must be protected by
a GFI receptacle or circuit. If a re-
ceptacle is used it must be readily
accessible.
To prevent electrical shock this unit
is an electrical appliance that is not
watertight and must be installed
as to prevent water from entering
the unit. This unit must be installed
away from showers, tubs, etc.
Never locate fireplace where it may
fall into a bathtub or other water
containers.
Holes for plastic
feet
Figure 5