Sump
Press
to put the product into standby.
Gently lift out the fuel-bed and place carefully on the ground.
Remove the water tank by lifting upwards.
Remove the sump lid, this allows the sump to be lifted completely from its location. (Fig 5).
Gently lift up the sump, taking care to keep level so as not to spill any water. Sit the assembly in the sink.
Carefully tilt so that the liquid drains out of the sump.
Put a small amount of washing up liquid into the sump, and using the supplied brush, gently clean all
surfaces including the metal disc (Fig 9).
When cleaned, thoroughly rinse the sump with clean water.
Clean the outlet surface of the sump lid with the brush and flush out thoroughly with water.
Reverse the above steps to reassemble.
Air Filter
1. Press
on the remote control or on the product to turn it off.
2. Gently lift off the fuel-bed and set aside.
3. Remove the tank and place in a sink with the cap facing upwards.
4. Gently slide up the air filter (Fig. 10).
5. Gently rinse with water in the sink and dry with fabric towel before returning.
6. Replace the filter making sure that the course black filter is in contact with the plastic holder.
7. Replace the tank.
8. Replace the fuel-bed.
9. Press
to turn on the product.
General Cleaning and Maintenance
The outside can be cleaned by wiping it over with a soft damp cloth and then dried. Do not use abrasive
cleaning powders or furniture polish, as this can damage the surface finish.
CAUTION:
Assembly, installation and repair of this heater must be carried out by Dimplex or its
authorised agent.
CAUTION:
We recommend that you arrange for this heater to be checked annually for safety by a
qualified electrician.