background image

 

        

 

 

Contact

 

Details

 

 

Please

 

note

 

that

 

some

 

of

 

the

 

contact

 

details

 

on

 

this

 

PDF

 

document

 

may

 

not

 

be

 

current.

 

 

Please

 

use

 

the

 

following

 

details

 

if

 

you

 

need

 

to

 

contact

 

us:

 

 

Telephone:

 

0844

 

879

 

3588

 

Email:

 

customer.services@gdcgroup.co.uk

 

 
 

The

 

customer

 

support

 

section

 

of

 

our

 

website

 

also

 

features

 

a

 

wide

 

range

 

of

 

information

 

which

 

may

 

be

 

of

 

use

 

to

 

you

 

and

 

is

 

available

 

24

 

hours

 

a

 

day.

 

It

 

includes:

 

 

 

Operating

 

and

 

installation

 

instructions

 

 

Easy

 

‘How

 

to

 

use’

 

guides

 

for

 

storage

 

heaters

 

 

Service

 

and

 

repairs

 

 

Where

 

to

 

buy

 

our

 

products

 

 

Literature

 

downloads

 

 

Heating

 

requirement

 

calculator

 

 
     

Visit

 ‐ 

www.dimplex.co.uk/support

 

A division of GDC Group Ltd 
Millbrook House   Grange Drive   Hedge End   Southampton   SO30 2DF 
www.dimplex.co.uk

 

Registered No: 1313016 England

VAT GB 287 1315 50004 

EEE Producer Registration Number – 

WEE/GE0057TS 

Paper from sustainable sources 

Summary of Contents for AX2

Page 1: ...h may be of use to you and is available 24 hours a day It includes Operating and installation instructions Easy How to use guides for storage heaters Service and repairs Where to buy our products Literature downloads Heating requirement calculator Visit www dimplex co uk support A division of GDC Group Ltd Millbrook House Grange Drive Hedge End Southampton SO30 2DF www dimplex co uk Registered No ...

Page 2: ...ax 01489 773053 GUARANTEE Dimplex UK Limited guarantee this Dimplex product for a period of two years from date of purchase against mechanical and electrical defects arising from faulty materials or from poor workmanship providing the product has been installed by a competent person in accordance with the fitting instructions Dimplex UK Limited undertake to repair or replace at their discretion wi...

Page 3: ...w power Water too cool or cold Water flow too high Reduce flow rate via temperature control Water pressure below minimum required See rating label Check water supply Reduction in ambient water temperature Select High power Water flow is poor Shower head is blocked Clean the showerhead Ensure showerhead is as specified by manufacturer The temperature control knob is set at its hottest setting Incre...

Page 4: ...o a tank supply unless a suitable booster pump is fitted 3 The minimum recommended running water pressure to which the shower heater may be connected is 15 lb sq in 1 Bar Running pressure at 8 litres per minute The maximum static pressure recommended is 150 lb sq in 10 Bar 4 The shower unit must not be fitted where it may be exposed to frost for example in an outdoor shower area The shower must no...

Page 5: ...y for servicing purposes Remove the two screws securing the shower unit cover and remove the cover complete with the control knobs Place the shower unit on the wall and mark the location of the fixing screws through the back plate Carefully drill the holes as marked using a sharp 5 5mm masonry drill Fix the shower unit to the wall using the plugs and screws provided do not fully tighten at this st...

Page 6: ...h the shower head NOTE When the temperature is changed the flow rate alters 11 Turn the top power selector knob to the STOP START position Outline Grey Symbol to stop the flow COMMISSIONING THE SHOWER OPERATING INSTRUCTIONS SECTION 10 Operating the shower 1 Switch on pull cord or wall mounted switch The Power neon will illuminate indicating the switch is on 2 Turn the top power selector knob to th...

Page 7: ...IMPORTANT Ensure that the terminal block screws are fully tightened and that no cable insulation is trapped under screws Ensure the cable clamp is used to secure the cable The earth continuity conductor of the electrical installation must be effectively connected to all SECTION 7 Fitting the cover into position NOTE It is necessary to align the D flat on the reverse side of the Power Selector and ...

Reviews: