background image

MAINTENANCE

Lamp Replacement

The lamps need to be replaced when you notice a dark section of the flame.  There are
four lamps under the log set which generate the flames and embers.

     It is a good idea to replace all of the lamps at one time if they are close to the end
     of their rated life.  Group replacement will reduce the number of times you need to open
     the unit to replace the lamps.

Warning:

Disconnect the power before attempting any maintenance or cleaning to reduce the risk
of fire, electric shock or injury  to persons.

Warning:

Allow at least 10 minutes for the lamps and heater to cool before attempting any main-
tenance or cleaning.

Bulb Requirements

Quantity 4 clear chandelier or candelabra lamps with an E-14  socket base, 60 watt
rating.

   

CAUTION DO NOT EXCEED 60 WATTS PER LAMP

   TO REPLACE LAMPS

1. Open the steel curtains.

2. Remove the log grate retaining screws and remove the log grate.

3. Pull the rear edge of the log set forward by grasping the ember bed by the sides

(handle the log set only by the ember bed and not the logs) and pulling firmly until
the rear tab pops out from under the back ledge, then lift out.

4. Examine to determine which lamps require replacement.

5. Unscrew lamp counter clockwise.

6. Insert  new lamp screwing clockwise.

7. Replace the log set by inserting the front edge, pushing the back down until the

rear tab snaps under the back ledge and the logs are resting against the mirror.

8. Replace log grate.

Summary of Contents for BF 30' series

Page 1: ...INSTALLATION USERS GUIDE FOR THE ELECTRIC INSERT FIREPLACE BF 30 series 7205131100rev01...

Page 2: ...of this manual 2 The heater on your fireplace may emit a slight harmless odor when first used This odor is a normal condition caused by the initial heating of internal heater parts and will not occur...

Page 3: ...applinace in front of a fixed socket outlet 16 To disconnect the fireplace turn the controls off then remove the plug from the socket outlet 17 Do not insert or allow foreign objects to enter any ven...

Page 4: ...edicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker or fuse trips Additional appliances may exceed the current r...

Page 5: ...lection controls FIGURE 2 for 3 seconds All 3 indicators will flash 5 Press the ON button on the transmitter Figure 1 the indicators will now flash rapidly and then turns off The transmitter and firep...

Page 6: ...he side of this switch has the same effect as the ON button on the remote control and the O side has the same effect as the OFF button of the remote control Pressing once to the left activates Level 1...

Page 7: ...in tenance or cleaning Bulb Requirements Quantity 4 clear chandelier or candelabra lamps with an E 14 socket base 60 watt rating CAUTION DO NOT EXCEED 60 WATTS PER LAMP TO REPLACE LAMPS 1 Open the ste...

Page 8: ...loss or damage arising out of the use of or inability to use the product The warranty will not apply if in the sole judgment of the Company damage or failure has resulted from accident alteration misu...

Reviews: