MAINTENANCE
Lamp Replacement
The lamps need to be replaced when you notice a dark section of the flame. There are
four lamps under the log set which generate the flames and embers.
It is a good idea to replace all of the lamps at one time if they are close to the end
of their rated life. Group replacement will reduce the number of times you need to open
the unit to replace the lamps.
Warning:
Disconnect the power before attempting any maintenance or cleaning to reduce the risk
of fire, electric shock or injury to persons.
Warning:
Allow at least 10 minutes for the lamps and heater to cool before attempting any main-
tenance or cleaning.
Bulb Requirements
Quantity 4 clear chandelier or candelabra lamps with an E-14 socket base, 60 watt
rating.
CAUTION DO NOT EXCEED 60 WATTS PER LAMP
TO REPLACE LAMPS
1. Open the steel curtains.
2. Remove the log grate retaining screws and remove the log grate.
3. Pull the rear edge of the log set forward by grasping the ember bed by the sides
(handle the log set only by the ember bed and not the logs) and pulling firmly until
the rear tab pops out from under the back ledge, then lift out.
4. Examine to determine which lamps require replacement.
5. Unscrew lamp counter clockwise.
6. Insert new lamp screwing clockwise.
7. Replace the log set by inserting the front edge, pushing the back down until the
rear tab snaps under the back ledge and the logs are resting against the mirror.
8. Replace log grate.