SCREWS
FIGURE 6
FIGURE 7
Screws
5
LIGHT BULB REQUIREMENTS
Quantity of 4 clear chandelier or candelabra bulbs with an E-14 socket base, 60 watt rating.
DO NOT EXCEED 60 WATTS PER BULB.
CAUTION
When handling log only apply force to the ember bed section not directly to the logs.
HELPFUL HINTS
It is a good idea to replace all light bulbs at one time if they are
close to the end of their rated life. Group replacement will
reduce the number of times you need to open the unit to
replace light bulbs. Long life bulbs are recommended to
reduce the frequency of bulb changes.
TO ACCESS THE LIGHT BULB AREA
1. Open steel curtain (remove glass doors if applicable).
2. Remove two screws on log bracket and set aside.
(FIGURE 6)
3. Pull front edge of plastic ember bed or plastic grate
up and forward until rear tab releases from the ledge
located at the bottom of the mirror. (FIGURE 7)
NOTE
Log set fi ts tightly into fi rebox, some force may be
necessary to remove.
4. Set logset in front of fi rebox.
5. Disconnect the logset LED wire harness from unit.
(FIGURE 8)
6. Examine the bulbs to determine which bulbs require
replacement.
7. Unscrew bulbs counter clockwise.
8. Insert new bulbs.
9. Re-connect the logset LED wire harness to the unit.
10. Replace the logset by inserting the rear tab of the logset
under the back ledge of the fi replace and push down
on the front edge of the logset until it snaps into place.
(FIGURE 7)
11. Replace log grate using two screws previously
removed.
PURIFIRE™ FILTER
The Purifi re™ fi lter supplied in your fi replace is
reusable and washable. The fi lter should be
cleaned or replaced on average once a year. To
clean the fi lter gently tap fi lter on a hard surface to
dislodge any loose dirt or debris, and then clean
with water. No soap or cleaning products are
recommended. The fi lter size is 508mm x 254mm x
25.4mm (20 inch x 10 inch x 1 inch) rated at MERV 10.
If using an after market fi lter follow the manufacturers
recommended replacement instructions.
LED Wire Harness
FIGURE 8