INSTALLATION GUIDE FOR THE  

OPTIFLAME ELECTRIC FIREPLACE 

LISTINGS AND CODE APPROVALS 

The BF series fireplaces have been tested in accordance with the UL 2021and CSA C22.2 No. 46 standards for 
fixed and location-dedicated electric room heaters.   

 

MODEL SPECIFICATIONS 

 

Model 

Number 

Description 

Voltage 

Volts 

Rated Power 

Watts 

 

Remote 

Control 

Wall 

Thermostat 

Refractory 
Brick Look 

AMPS 

120Volt 

AMPS 

208Volt 

AMPS 

240Volt 

BF36E 36” 

Economy 

120/208/240 1650/2340/3025  N/A N/A  N/A 13.75 11.25  12.6 

BF36ST 36” 

Standard 

120/208/240 1650/2340/3025 Included Included 

N/A 

13.75  11.25  12.6 

BF36DX 36” 

Deluxe 

120/208/240 1650/2340/3025 Included Included  Included  13.75  11.25  12.6 

BF42ST 42” 

Standard 

120/208/240 1650/2340/3025 Included Included 

N/A 

13.75  11.25  12.6 

BF42DX 42” 

Deluxe 

120/208/240 1650/2340/3025 Included Included  Included  13.75 

 

11.25 

 

12.6 

 

 

NOTE: Power ratings shown include the light bulbs and motor (275 watts)

 

STEP-BY-STEP INSTALLATION 

(Note: Please read all instructions before installing)

 

1.  Rough in framing opening following the recommended dimensions (Section A: Framing). 
 
2.  Allow 8” of service cable for connecting to the junction box on the fireplace.  Remove the outer jacket and 

strip the individual conductors ½” from the end. 

 

3.  Loosen the screw securing junction box cover and remove the cover. 

 

4.  Remove knockouts if necessary or use the provided cable clamp. 

 

5.  Place unit in position in the opening, level with shims if necessary and attach unit to frame using nailing 

flanges provided. 

 

6.  Unit is factory wired for 208/240 volt power supply.  If 120 volt operation is required, slide the switch and 

reconfigure the wiring as covered in section C wiring. Wires L1, L2, N & G are attached to the rear of the 
junction box cable clamp for easy access. 

 

7.  Wire a dedicated, properly fused circuit with a 20amp rating for the appropriate voltage (120, 208/240).  

 

8.  Make wall mounted thermostat and or wall switch connections as outlined in Section C: Wiring.  

 

9.  Place all connectors inside the unit and replace the junction box cover, ensuring that the cable clamp grips 

only the jacket of service, thermostat and if applicable wall switch lines. 

 
 

7205180100REV01 

Summary of Contents for BF36DX

Page 1: ...before installing 1 Rough in framing opening following the recommended dimensions Section A Framing 2 Allow 8 of service cable for connecting to the junction box on the fireplace Remove the outer jac...

Page 2: ...ational electrical codes for rated power consumption For 208 240 volt installations use three conductor non metallic sheath cable with ground wire for the incoming power supply on Optiflame fireplace...

Page 3: ...the green ground wire from the unit to the ground from the power supply 7 When the unit has been configured for the appropriate power supply voltage ensure that all connections are tight Insert all th...

Page 4: ...h on the top corner of the unit and ensure that the power conversion switch is in the proper position for the required supply voltage 2 Loosen the screw securing the junction box and remove the cover...

Page 5: ...at 1 Locate the switch on the top corner of the unit and ensure that the power conversion switch is in the proper position for the required supply voltage 2 Loosen the screw securing the junction box...

Page 6: ...orner of the unit 2 Flip the switch from 230 volt to 115 volt configuration 3 Loosen the screw securing the junction box cover and remove the cover 4 Remove the knockouts if necessary or use the provi...

Page 7: ...and remove the cover 4 Remove the knockouts if necessary or use the provided cable clamp 5 Pull out the four wires marked L1 L2 N and G 6 Connect one of the wires from the wall switch to the black L1...

Page 8: ...WIRING DIAGRAM WITH REMOTE CONTROL...

Page 9: ...WIRING DIAGRAM WITHOUT REMOTE CONTROL...

Page 10: ...1367 Industrial Road Cambridge Ontario Canada N1R 7G8 1 888 DIMPLEX 1 888 346 7539 Approved for use in the United States and Canada...

Reviews: