SECTION A:  FRAMING  

Optiflame Dimensions

 

 
 
 

 

Rough-in framing dimensions  

      Optiflame dimensions            Rough-in corner framing dimensions 

 

This fireplace is a zero clearance design.  Combustibles may be installed to the edge of the unit. A drywall lip at the 
top of the unit and four nailing flanges on the sides of the unit are provided on each unit to facilitate installation.  
Insulation and vapor barrier should be placed a minimum of 2 inches from the unit.   

SECTION B: RECOMMENDED POWER SUPPLY WIRE SPECIFICATIONS 

For 120 volt installations use two conductor, non-metallic sheath cable with ground wire for the incoming power 
supply on Optiflame fireplace inserts.  Use the appropriate wire to meet local and national electrical codes for rated 
power consumption.   

 

For 208 / 240 volt installations use three conductor, non-metallic sheath cable with ground wire for the incoming 
power supply on Optiflame fireplace inserts. Use the appropriate wire to meet local and national electrical codes for 
rated power consumption. 

 

 

Two conductor, non-metallic sheath cable with ground wire is recommended for installation of a wall mounted 
thermostat and/or switch on Optiflame fireplace inserts.  Use appropriate wire to meet local and national electrical 
codes for rated power consumption.  Thermostat/wall switch wire gauge must match the recommended wire sizes 
shown below. 

 

 

 

 

 

RECOMMENDED WIRE AND FUSING REQUIREMENTS 

 

 

 

VOLTS 

WIRE GAUGE 

 

  FUSE RATING 

120 VOLT 

12 GAUGE 

20 AMP 

208 VOLT 

14 GAUGE 

15 AMP 

240 VOLT 

12 GAUGE 

20 AMP 

 

MODEL 

A B C D E F 

BF36E/ST/DX 35.5”  38.7”  54.0” 38.0” 38.0” 39.5” 
BF42ST/DX 41.5” 44.7”  60.0” 42.0” 42.0” 45.5” 

Summary of Contents for BF36DX

Page 1: ...before installing 1 Rough in framing opening following the recommended dimensions Section A Framing 2 Allow 8 of service cable for connecting to the junction box on the fireplace Remove the outer jac...

Page 2: ...ational electrical codes for rated power consumption For 208 240 volt installations use three conductor non metallic sheath cable with ground wire for the incoming power supply on Optiflame fireplace...

Page 3: ...the green ground wire from the unit to the ground from the power supply 7 When the unit has been configured for the appropriate power supply voltage ensure that all connections are tight Insert all th...

Page 4: ...h on the top corner of the unit and ensure that the power conversion switch is in the proper position for the required supply voltage 2 Loosen the screw securing the junction box and remove the cover...

Page 5: ...at 1 Locate the switch on the top corner of the unit and ensure that the power conversion switch is in the proper position for the required supply voltage 2 Loosen the screw securing the junction box...

Page 6: ...orner of the unit 2 Flip the switch from 230 volt to 115 volt configuration 3 Loosen the screw securing the junction box cover and remove the cover 4 Remove the knockouts if necessary or use the provi...

Page 7: ...and remove the cover 4 Remove the knockouts if necessary or use the provided cable clamp 5 Pull out the four wires marked L1 L2 N and G 6 Connect one of the wires from the wall switch to the black L1...

Page 8: ...WIRING DIAGRAM WITH REMOTE CONTROL...

Page 9: ...WIRING DIAGRAM WITHOUT REMOTE CONTROL...

Page 10: ...1367 Industrial Road Cambridge Ontario Canada N1R 7G8 1 888 DIMPLEX 1 888 346 7539 Approved for use in the United States and Canada...

Reviews: