background image

Installation Guide

Model

BFSL33

IMPORTANT SAFETY INFORMATION: 

Always read this manual first 

before attempting to install or use this fireplace. For your safety, always 

comply with all warnings and safety instructions contained in this manual 

to prevent personal injury or property damage.

 

 

To view the full line of Dimplex products, please visit

 

www.dimplex.com

7211030100rev00

Summary of Contents for BFSL33

Page 1: ...irst before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage T...

Page 2: ...Power Wall Switch Wiring 10 Wiring For 240 Volt 10 Wiring For 120 Volt 12 Wiring For 120 Volt No Heat Installation 14 Section E 16 Heater Wall Switch Wiring For 120 240 Volt 16 Wall Mounting Thermost...

Page 3: ...connecting power supply wire to junction box on fireplace when installing after finishing wall Remove the outer jacket and strip the individual conductors from the end Loosen the screw securing the j...

Page 4: ...three trim pieces top and two sides The top piece is secured with screws at either end and one in the middle The two side pieces require a tab to be inserted in the center slot then secured with a sc...

Page 5: ...Use the appropriate wire to meet local and national electrical codes for rated power consumption For 208 240 volt installations use three conductor non metallic sheath ca ble with ground wire 4 wires...

Page 6: ...sert a flat headed screwdriver inside the exhaust panel to change the switch from 240 volts 230 position to 120 volts 115 position When wiring the unit for 208 240 volts the voltage selector switch sh...

Page 7: ...volt position 230 is printed on 2 switch Loosen the screw securing the junction box cover and remove the cover 3 Remove the knockouts if necessary or use the provided cable clamp 4 Pull out the four w...

Page 8: ...5 is 2 printed on switch Loosen the screw securing the junction box cover and remove the cover 3 Remove the knockouts if necessary or use the provided cable clamp 4 Pull out the four wires marked L1 L...

Page 9: ...nted on switch Loosen the screw securing the junction box cover and remove the cover 3 Remove the knockouts if necessary or use the provided cable clamp 4 Pull out the four wires marked L1 L2 N and G...

Page 10: ...7 the L1 terminal of the main power wall switch Connect the red L2 wire from the unit to the red L2 wire from the main 8 power wall switch by using a wire connector not supplied Connect the other end...

Page 11: ...11 240 Volt Main Wall Switch Wiring Diagram FIREPLACE JUNCTION bOX 240 v POWER SUPPLY bREAKER PANEL WHITE N RED L2 BLACK L1 WHITE N BLACK L1 GROUND G WALL SWITCh RED L2 GROUND G...

Page 12: ...1 wire from the 6 main power wall switch using a wire connector not supplied Connect the other end of the black L1 wire to the L1 terminal of the main 7 power wall switch Connect the red L2 wire from...

Page 13: ...13 120 Volt Main Wall Switch Wiring Diagram FIREPLACE JUNCTION bOX 120 v POWER SUPPLY bREAKER PANEL WHITE N RED L2 BLACK L1 WHITE N BLACK L1 GROUND G WALL SWITCh GROUND G...

Page 14: ...main power wall switch using a wire connector not supplied Connect the other end of the black L1 wire to the L1 terminal of the main 7 power wall switch Connect the red L2 wire from the unit and the...

Page 15: ...Volt Main Wall Switch Wiring Diagram No Heat Installation FIREPLACE JUNCTION bOX 120 v POWER SUPPLY bREAKER PANEL WHITE N RED L2 BLACK L1 WHITE N BLACK L1 GROUND G WALL SWITCh GROUND G RED 1 RED 2 WIR...

Page 16: ...the black L1 wire from the 5 heater wall switch by using a wire connector not supplied Connect the other end of black L1 wire from the heater wall switch to the 6 L1 terminal of the heater wall switch...

Page 17: ...17 Heater Wall Switch Wiring Diagram For 120 240 Volt See Section C or Section D For Main Power Connection FIREPLACE JUNCTION bOX WALL ThERMOSTAT RED 1 GROUND G RED 2...

Page 18: ...nect the red 1 wire from the unit to the white neutral wire from the 5 wall thermostat box by using a wire connector not supplied Connect the other end of the white neutral wire from the thermostat wa...

Page 19: ...19 Wall Mounted Thermostat Wiring Diagram For 120 240 Volt See Section C or Section D For Main Power Connection FIREPLACE JUNCTION bOX WALL ThERMOSTAT RED 1 GROUND G RED 2...

Page 20: ...the blue 3 wire from the unit to the black L1 wire from the 5 flame override wall switch by using a wire connector not supplied Connect the other end of the black L1 wire from the flame override wall...

Page 21: ...me Override Wall Switch Wiring Diagram For 120 240 Volt See Section C or Section D For Main Power Connection NOT AVAILABLE WITH NO HEAT INSTALLATION FIREPLACE JUNCTION bOX BLUE 4 WALL SWITCh BLUE 3 GR...

Page 22: ...OR D D LED DRIVER BOARD LED PCB BOARD BLACK AC L WHITE AC N RED DC YELLOW DC SPECIAL NOTE ON LED BOARD CONNECTION BOTH AC AND DC POLARITIES MUST BE CONNECTED AS SHOWN TO MAKE LED WORK F F T T LOGSET D...

Reviews: