18
W
all
M
ounTing
T
herMosTaT
W
iring
f
or
120/240 v
olT
!
NOTE:
Before installing the unit complete the following:
Install main power connection with appropriate voltage as per Section C
•
or Section D.
Install a 2 conductor wire with ground (3 wires total) from the thermostat
•
wall box to the junction box on the unit.
!
NOTE:
Wiring of the thermostat must be completed prior to installing the
unit.
!
NOTE:
The following installation instructions are for a single pole thermo-
stat.
Loosen the screw securing the junction box and remove the cover.
1.
Remove the knockouts (if necessary) or use the provided cable clamp.
2.
Pull out the three wires marked 1, 2, and G. (red, red, and green).
3.
Remove the wire connector and separate the wires marked 1 & 2.
4.
Connect the (red) 1 wire from the unit to the white (neutral) wire from the
5.
wall thermostat box by using a wire connector. (not supplied)
Connect the other end of the white (neutral) wire from the thermostat wall
6.
box to the red wire from the wall thermostat.
Connect the (red) 2 wire from the unit to the black wire from the thermo-
7.
stat wall box by using a wire connector. (not supplied)
Connect the other end of the black wire from the thermostat wall box to
8.
the black wire from the wall thermostat.
Connect the green (ground) wire from the unit to the green (ground) wire
9.
from the thermostat wall box by using a wire connector. (not supplied)
Connect the other end of the green (ground) wire to the thermostat wall
10.
box ground screw.
Ensure that all connections are tight.
11.
Insert all the wiring of the wall mounted thermostat into the wall box.
12.
Insert all the wiring back into the unit and secure with a cable clamp.
13.