background image

            www.dimplex.com

Maintenance

  

WARNING:

 Disconnect power before attempting any 

maintenance or cleaning to reduce the risk of fire, elec

-

tric shock or damage to persons.

Filling the water tank

When the water tank is empty, the flame effect shuts off 

and you will hear 2 audible beeps, follow these steps.

 CAUTION: 

Allow at least five minutes for components to 

cool before disassembling the unit to refill.

1.  Turn the On/Off switch to the off position 

(0)

 (Figure 1)

2.  Gently remove the log media and place them carefully 

on the ground. 

3. 

Remove the refill container by lifting upwards and 

outwards. 

4. 

Refill the container with tap water.

 

!

 NOTE:  

Normal tap water can be used in the Optimyst

®

 

as long as the tap water is not considered to be hard water.  
In the event your tap water is hard, you may use softened 

water or distilled water with 1/8 tsp of salt (0.5 mL) added to 

the water reservoir.  

(

The addition of additional salt should 

only be when you notice that the unit is not producing mist 

as expected.)

5.  Screw the cap back on, 

do not overtighten

6. 

Return the refill container to the sump, with the tank 

cap facing down and the flat side of the tank facing 

outward. 

7.  Gently place the log media back into position.

8.  Turn the On/Off switch to the off position 

(I).

 (Figure 1)

If you do not intend on using the unit for longer than 2 
weeks, empty and drain the unit of water, and dry all of the 
water containing components.

Replacing the Light bulbs

If a large amount of the smoke appears grey or colourless it 
may be that one or more of the light bulbs have burnt out. 

 CAUTION: 

Allow at least twenty minutes for light bulbs 

to cool before touching bulbs to avoid accidental burning of 
skin.

1. 

Leaving the flame effect on, remove the rock media, 

tray and water tank and lift out the top cover (Figure 3).

2. 

View the lamps from a distance in front of the fire and 

observe which lamp needs to be changed.

3.  Turn the unit off, and unplug the engine.

4.  Leave the appliance for 20 minutes to allow the lamps 

to cool down before removing them.

5. 

Remove the water tank and sump (Figure 4) by lifting 

upwards and placing to the side. 

6.  Remove the defective bulb, by gently lifting vertically 

and disengaging the pins from the lamp holder. 

!

 NOTE: 

Replacement light bulbs can be obtained by 

contacting Dimplex Customer Service at

 1-888-346-7539.

7.  Carefully insert the two pins of the new bulb into the 

two holes in the lamp holder. Push lamp firmly in place.

8. 

Replace the top cover, refill container and log media.

Cleaning

It is recommended that all of the components that contain 
water are cleaned with soap and water on a 

biweekly

 ba-

sis.  A small brush has been included to assist in cleaning 

difficult items/areas, i.e. the transducer.

 CAUTION: 

Do not put plastic components in the dish-

washer.

Filter Cleaning

The air filter can be removed and gently rinsed with water 

to clean and dried on a towel before reinstalling.

!

 NOTE: 

Replace the filter so that the course black filter is 

facing the front of the engine.

Surface Cleaning

Use a warm damp cloth only to clean surfaces of the en-
gine. Do not use abrasive cleaners.

!

 NOTE: 

If you need to move the unit ensure that all of 

the components that contain water have been emptied be-
fore relocating.

Top 
Cover

Figure 3

Transducer

Emitter

Wire Slot

Retaining 
Tabs

Water 
Reservoir

Figure 4

Sump

Filter

Summary of Contents for BOF4056

Page 1: ...tice 2014 Dimplex North America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1 888 346 7539 www dimplex com REV PCN DATE 00 7 MAY 14 IMPORTANT SAFETY INFORMAT...

Page 2: ...niques which if not carefully followed will expose the user to the risk of fire serious injury or death Operation 3 Maintenance 4 Exploded Parts Diagram 5 Replacement Parts 5 Wiring Diagram 6 Remote C...

Page 3: ...cycling advice in your area Operation NOTE When the engine is used in an environment where background noise is very low it may be possible to hear a sound which is related to the operation of the flam...

Page 4: ...AUTION Allow at least twenty minutes for light bulbs to cool before touching bulbs to avoid accidental burning of skin 1 Leaving the flame effect on remove the rock media tray and water tank and lift...

Page 5: ...Container 0441440300RP 8 Top Cover Assembly 9600670100RP 9 Water Reservoir Sump 0441380100RP 10 Fan Assembly 5300300100RP 11 Fan Housing Assembly 9600540100RP 12 Fan Filter 8600300100RP 13 Transducer...

Page 6: ...6 www dimplex com Wiring Diagram...

Page 7: ...the unit 5 Transfer the wire connectors from the terminals on the original board to the same location on the replacement board NOTE Use a flat head screwdriver to gently pry between the end of the co...

Page 8: ...iometer Replacement Tools Required Philips head screwdriver Flat Head Screwdriver 3 8 10mm Wrench WARNING Disconnect power before attempting any maintenance to reduce the risk of electric shock or dam...

Page 9: ...r before attempting any maintenance to reduce the risk of electric shock or damage to persons NOTE Ensure that all of the components that contain water have been emptied before performing any maintena...

Page 10: ...intenance 1 Remove the 10 screws that attach the heater assembly to the support plate Figure 8 1 Remove the 4 screws securing the heater support plate to the unit Figure 8 2 Gently drop the support pl...

Page 11: ...ch A is in the ON I position but mode Switch B has not been pressed Figure 2 Press Switch B once for flame effect Figure 2 Low water level Check the water tank is full and there is water in the sump W...

Page 12: ...the heater is initially turned on The heater is burning off any dust accumulated during manufacturing or operation Defective heater assembly Replace heater assembly Heater fan turns on but heater lack...

Reviews: