This heater must be used on an AC ~ supply only and the voltage marked on the heater must 

correspond to the supply voltage. Before switching on, please read the safety warnings and 

operating instructions. Please retain this user’s guide for future reference

Ensure that all packing items are removed (read any warning labels carefully). Retain all packing 

for possible future use e.g. in the event of moving or returning the appliance to your supplier.

To install the appliance;

1.   Clean the area where the fire will be installed.

2.   Hold the fire by the sides of surround and gently manoeuvre into position. 

3.    Plug the fire into a 13amp/240 volt outlet. Ensure that the supply cable is not trapped under 

the fire such that it might cause it to be damaged.

4.   Ensure that the draft excluder (rubber strip) is fitted to the channel on the base of the product.

Connecting the Transducer

1.    Gently lift out the fuelbed and carefully set aside. (Fig 3)

2.    Remove the water tank by lifting upwards and outwards. (Fig 4)

3.    Remove the nozzle by unclipping and lifting upwards and outwards. (Fig 5)

4.    The transducer will be inside the sump. Remove from its bag.

5.    Place the Transducer unit into the sump and make the connection.

6.    Locate the tab on the Transducer unit into the moulded recess in the base of the sump (Fig 6)

7.    Ensure that the cable does not obstruct the Transducer disc. To prevent the cable becoming 

pinched between the nozzle and the sump, place the cable in the slot in the wall of the sump. 

(Fig 7)

Filling the Water Tank

1.   Gently lift out the fuelbed and carefully set aside.

2.   Remove the water tank by lifting upwards and outwards.

3.   Place the water tank in sink and remove cap, Anti-clockwise to open. (Fig 8)

3.    

Fill tank with filtered tap water only. This is necessary to prolong the life of the flame and 

smoke producing unit. The water should be filtered through a conventional domestic water 

filter unit and the filter should be replaced regularly.

6.    Screw the cap back on, do not over tighten.

7.    Return the tank to the sump, with the tank cap facing down

8.    Gently place the fuelbed back into position.

When the water tank is empty, the flame and smoke effect shuts off, you will hear 2 audible beeps 

and the digital display will display 

Installation Instructions

4

Summary of Contents for Bramdean BMD20

Page 1: ...gner seg kun for godt isolerte rom eller sporadisk bruk RO Acest produs este adecvat exclusiv spa iilor bine ventilate sau utiliz rii ocazionale CZ Tento v robek je vhodn pouze do dob e izolovan ch pr...

Page 2: ...3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or ins...

Page 3: ...operation of the flame effect This is normal and should not be a cause for concern The sump and the water tank in this product are treated with a biocidal product Silver Biocide in order to control ha...

Page 4: ...pping and lifting upwards and outwards Fig 5 4 The transducer will be inside the sump Remove from its bag 5 Place the Transducer unit into the sump and make the connection 6 Locate the tab on the Tran...

Page 5: ...ature the heat function will not operate The temperature range is from 15 35 C Press it a third time and you will be in the Fire mode The display will show followed by the current fire effect setting...

Page 6: ...on remove any obstruction that may be restricting the heat outlet then continue normal operation CAUTION In order to avoid a hazard due to inadvertent resetting of the thermal cutout this appliance m...

Page 7: ...o spill any water Sit the assembly in the sink Carefully tilt so that the liquid drains out of the sump Put a small amount of washing up liquid into the sump and using the supplied brush gently clean...

Page 8: ...r assistance with this product please go to www dimplex co uk and select Customer Support or ring our help desk on 0344 879 3588 UK or 01 8428 222 R O I Spare parts are also available on the web site...

Page 9: ...lame effect is set too low Increase level of flame by pressing three times to get you into mode Press to increase the flame setting The Metal Disc in the transducer might be dirty Clean the Metal Disc...

Page 10: ...Fig 1a 123 mm 670 mm 566 mm 217 mm Fig 1b Fig 2 10...

Page 11: ...Fig 4 Fig 3 Fig 6 Fig 5 11...

Page 12: ...Fig 8 Fig 7 Fig 10 Fig 9 A B 12...

Page 13: ...Notes 13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...ex Millbrook House Grange Drive Hedge End Southampton SO30 2DF Glen Dimplex Heating and Ventilation All rights reserved Material contained in this publication may not be reproduced in whole or in part...

Reviews: