** After the unit has shut down due to an error, a full reset of the unit will be required by turning the unit Off with the On/

Off switch for 60 seconds then turning back On.

PROBLEM

CAUSE

SOLUTION

General

Unpleasant smell when unit 

is used.

Dirty or stale water.

Clean the unit as described under maintenance.

Appearance

Fireplace does not turn on 

Manually (unit does not 

beep when switch turned)

Improper operation

Refer to Operation Section

No incoming voltage from the electrical wall 

socket

Check Fuse/Breaker Panel

Defective main control board

Replace main control board

Only one side of the unit is 

operating

Tethered controller not installed correctly

Ensure that connection has clicked into place

Put unit in troubleshooting mode to test any of 

the functions listed

If none of the tests are working, replace the main 

control board

Fireplace does not turn on 

with the Remote Control

Improper operation

Refer to Operation Section

The batteries in the remote control are dead

Install new battery into the remote control  

Tethered controller not installed correctly

Ensure that connection has clicked into place

Remote not initialized with the unit

Initialize remote to unit.  Unit will flash on and off 

during initialization, completion will be indicated with 

5 beeps

Remote signal is not being received by teth-

ered controller

Ensure that tethered controller is in an open area that 

can receive signal from remote control

Defective remote control (blue light on end of 

remote does not turn on when buttons are 

pressed)

Replace remote control

Defective tethered controller

Replace tethered controller

Defective remote control

Replace remote control

The flame effect has too 

much smoke or is coming 

out too fast

Flame effect control is set too high

Adjust the flame height on both the secondary and/or 

primary controls

Filter is missing off of Fan Housing

Replace Fan Filter

Mist is not coming out 

evenly

Condensation building up on the mist outlet

Remove the build up of condensation

Unit is not level

Adjust the feet under the unit to ensure that the unit 

has been installed level, front to back and side to side

Media is blocking air flow

Rearrange media to ensure mist outlet is not being 

blocked

The transducer is not operating correctly - put 

the unit in troubleshooting mode to test 

the transducer

If the transducer is running, ensure that the emitter is 

clean and free of calcium deposits or scaling
If the transducer is not running, replace the trans-

ducer with the provided additional transducer

The flame effect is too low

Flame effect control is set too low

Adjust the flame height on both the secondary and/or 

primary controls

Verify that the unit is receiving 72 in

2

 (460 cm

2

of air

Enlarge area for air to enter unit

The fan is not operating correctly - put unit in 

troubleshooting mode to test the fan

If the fan is not running, replace fan assembly
If the fan is running, ensure that the air filter is clean 

and dry

The heating element is not operating correctly 

- put unit in troubleshooting mode to test 

the operation of the heating element

Replace the heating element

Unit is blinking every 8 sec-

onds and is not operating

Water level in reservoir is too high **

Remove enough water from reservoir so that level is 

below maximum level

The solenoids are not operating correctly - put 

unit in troubleshooting mode to test the opera-

tion of the solenoids

If the solenoids are not working, replace the solenoid

TROUBLESHOOTING GUIDE

Summary of Contents for CDFI1000P

Page 1: ...h America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N3H 4W3 1 888 346 7539 www dimplex com REV PCN DATE 00 21 12 15 IMPORTANT SAFETY INFORMATION Always read this m...

Page 2: ...carefully followed will expose the user to the risk of fire serious injury or death Operation 3 Maintenance 4 Exploded Parts Diagram 5 Replacement Parts List 5 Wiring Diagram 6 Switch Board Replacemen...

Page 3: ...d The unit has two separate internal modules that are con trolled by the settings entered on the left side primary Finer adjustment can be done using the controls on the right module to have both modu...

Page 4: ...t After prolonged usage the ability for the unit to produce mist may become reduced When this occurs the replace ment of the transducer may be required This unit comes with 2 additional transducers lo...

Page 5: ...1320100RP 8 Solenoid Valve 9601330100RP 9 Top Cover Assembly 9601220100RP 10 Fan Assembly 9601310100RP 11 Fan Filter 8600300100RP 12 Transducer 9601210100RP 13 LED Light Assembly 9601250100RP 14 Remot...

Page 6: ...6 www dimplex com WIRING DIAGRAM FUSE...

Page 7: ...er from the instructions above Figure 4 TERMINAL BLOCK REPLACEMENT Tools Required Phillips head screwdriver WARNING Disconnect power before attempting any maintenance to reduce the risk of electric sh...

Page 8: ...cs assembly CAUTION Ensure that the switchboard and terminal block have not moved from their original locations and all wires are contained under the cover before reassembly 9 Re assemble the remainde...

Page 9: ...s and reinsert the electronics assembly CAUTION Ensure that the switchboard and terminal block have not moved from their original locations and all wires are contained under the cover before reassembl...

Page 10: ...bly CAUTION Ensure that the switchboard and terminal block have not moved from their original locations and all wires are contained under the cover before reassembly 10 Re assemble the remainder of th...

Page 11: ...ronics assembly CAUTION Ensure that the switchboard and terminal block have not moved from their original locations and all wires are contained under the cover before reassembly 11 Re assemble the rem...

Page 12: ...o prevent strain on the connector wire attached to it 4 Remove the cable clamp to allow for the assembly to be lifted out to better access the components 5 Holding the assembly at either end of the LE...

Page 13: ...ontrol Replace remote control The flame effect has too much smoke or is coming out too fast Flame effect control is set too high Adjust the flame height on both the secondary and or primary controls F...

Page 14: ...water source Improper operation Mist will begin emitting out of the unit after 45 sec onds of operation Transducer is not installed correctly Ensure that the connection has clicked into place Cord is...

Page 15: ...the toggle switch in the On position and everything else Off 2 Press the troubleshooting button Figure 1D on the side that the testing is required unit will beep 3 Press the following buttons to test...

Reviews: