background image

7

SWITCH BOARD REPLACEMENT 

Tools Required:

  Phillips head screwdriver

  WARNING:

  Disconnect power before attempting any 

maintenance to reduce the risk of electric shock or damage 

to persons.

!

 NOTE: 

Ensure that all of the components that con-

tain water have been emptied and source water has been 

turned off before performing any maintenance.
1.  Disconnect and remove the media tray or log set from 

the unit and put them in a safe place.

2.  On the side the replacement is required, remove the 

securing screws and metal wire cover.

3.  Remove the 4 screws and the electronics cover from 

the unit. (Figure 4)

!

 NOTE: 

Use caution when removing the electronics 

cover, to prevent strain on the connector wire attached to it.
4.  Locate the switch board to be replaced.
5.  Gently lift the switch board off of the mounting stands.
6.  Disconnect the wire connection from the back of the 

board.

7.  Attach the wire connection to the new board and place 

on the mounting stands.

8.  Re-assemble the remainder of the cassette in reverse 

order from the instructions above.

Figure 4

TERMINAL BLOCK REPLACEMENT 

Tools Required:

  Phillips head screwdriver

  WARNING:

  Disconnect power before attempting any 

maintenance to reduce the risk of electric shock or damage 

to persons.

!

 NOTE: 

Ensure that all of the components that con-

tain water have been emptied and source water has been 

turned off before performing any maintenance.
1.  Disconnect and remove the media tray or log set from 

the unit and put them in a safe place.

2.  On the secondary side remove the securing screws 

and metal wire cover.

3.  Remove the 4 screws and the electronics cover from 

the unit. (Figure 4)

!

 NOTE: 

Use caution when removing the electronics 

cover, to prevent strain on the connector wire attached to it.
4.  Locate the terminal block to be replaced.
5.  Disconnect the wire connections from the original block 

and install it on the new block.

6.  Replace the terminal block in the original position - the 

terminal block is located so that it sits on the moulded 

pins on the surface below.

7.  Re-assemble the remainder of the cassette in reverse 

order from the instructions above.

Electronics Cover (2)

Fan (2)

Power Supply (2)

Main Power Board (2)

LED Light Assembly (2)

Terminal Block

Switch Board (2)

Summary of Contents for CDFI1000P

Page 1: ...h America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N3H 4W3 1 888 346 7539 www dimplex com REV PCN DATE 00 21 12 15 IMPORTANT SAFETY INFORMATION Always read this m...

Page 2: ...carefully followed will expose the user to the risk of fire serious injury or death Operation 3 Maintenance 4 Exploded Parts Diagram 5 Replacement Parts List 5 Wiring Diagram 6 Switch Board Replacemen...

Page 3: ...d The unit has two separate internal modules that are con trolled by the settings entered on the left side primary Finer adjustment can be done using the controls on the right module to have both modu...

Page 4: ...t After prolonged usage the ability for the unit to produce mist may become reduced When this occurs the replace ment of the transducer may be required This unit comes with 2 additional transducers lo...

Page 5: ...1320100RP 8 Solenoid Valve 9601330100RP 9 Top Cover Assembly 9601220100RP 10 Fan Assembly 9601310100RP 11 Fan Filter 8600300100RP 12 Transducer 9601210100RP 13 LED Light Assembly 9601250100RP 14 Remot...

Page 6: ...6 www dimplex com WIRING DIAGRAM FUSE...

Page 7: ...er from the instructions above Figure 4 TERMINAL BLOCK REPLACEMENT Tools Required Phillips head screwdriver WARNING Disconnect power before attempting any maintenance to reduce the risk of electric sh...

Page 8: ...cs assembly CAUTION Ensure that the switchboard and terminal block have not moved from their original locations and all wires are contained under the cover before reassembly 9 Re assemble the remainde...

Page 9: ...s and reinsert the electronics assembly CAUTION Ensure that the switchboard and terminal block have not moved from their original locations and all wires are contained under the cover before reassembl...

Page 10: ...bly CAUTION Ensure that the switchboard and terminal block have not moved from their original locations and all wires are contained under the cover before reassembly 10 Re assemble the remainder of th...

Page 11: ...ronics assembly CAUTION Ensure that the switchboard and terminal block have not moved from their original locations and all wires are contained under the cover before reassembly 11 Re assemble the rem...

Page 12: ...o prevent strain on the connector wire attached to it 4 Remove the cable clamp to allow for the assembly to be lifted out to better access the components 5 Holding the assembly at either end of the LE...

Page 13: ...ontrol Replace remote control The flame effect has too much smoke or is coming out too fast Flame effect control is set too high Adjust the flame height on both the secondary and or primary controls F...

Page 14: ...water source Improper operation Mist will begin emitting out of the unit after 45 sec onds of operation Transducer is not installed correctly Ensure that the connection has clicked into place Cord is...

Page 15: ...the toggle switch in the On position and everything else Off 2 Press the troubleshooting button Figure 1D on the side that the testing is required unit will beep 3 Press the following buttons to test...

Reviews: