13

Figure 6

Flicker

Rod

replace light bulbs.  Care must be 

taken when removing the log set.  

To Access The Lower Light 

Bulb Area: 

(Figure 6)

 

CAUTION: 

Allow at least 5 

minutes for light bulbs to cool 

before touching bulbs to avoid ac-

cidental burning of skin.
1.  Remove front glass assembly.
2.  Pull the back edge of the 

plastic ember bed forward 

until the rear tab releases 

from the ledge located at the 

bottom of the partially reflec-

tive glass.

!

IMPORTANT:  

Only handle the 

log set by the ember bed.

!

NOTE:  

Log set fits tightly into 

firebox, some force may be nec-

essary to remove.
3.  Set log set in front of fire-

place.

Figure 7

Side Section

Front

Edge

Log 

Ember 

Bed

Back

Ledge

Rear

Tab

  Maintenance

4.  Disconnect the flicker rod 

from the motor (see Figure 6).

5.  Unscrew bulbs counter clock-

wise.

6.  Insert new bulbs.
7.  Reconnect the flicker rod to 

motor.

8.  Replace the log set by insert-

ing the front edge of the log 

set and push down on the 

rear edge of the ember bed 

until it snaps into place (Fig-

ure 7).

!

 NOTE:  

Ensure the log set is 

installed tightly under the back 

ledge to prevent light leakage.
9.  Replace glass assembly.

Glass Cleaning

The front glass is cleaned in the 

factory during the assembly op-

eration.  During shipment, instal-

lation, handling, etc., the front 

Summary of Contents for DF2426

Page 1: ...l first before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damag...

Page 2: ...emphasize CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose the us...

Page 3: ...ranty Please record your model and serial numbers below for future reference model and serial numbers can be found on the Model and Serial Number Label of your fireplace NO NEED TO RETURN TO THE STORE...

Page 4: ...or if the electric fireplace has been dropped or damaged in any man ner contact Dimplex Technical Service at 1 888 346 7539 IMPORTANT INSTRUCTIONS Do not use outdoors The electric fireplace is not in...

Page 5: ...ys plug heaters directly into a wall outlet receptacle Never use with an extension cord or relocatable power tap outlet power strip Do not burn wood or other ma terials in the electric fireplace Do no...

Page 6: ...e the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult...

Page 7: ...flammable vapors or liquids in the vicinity of the heater CAUTION Clearance for air circulation beneath the fire place insert is provided by 2 rubber feet Do not install the fireplace insert directly...

Page 8: ...t circuit is required A dedicated circuit is preferred but not es sential in all cases A dedi cated circuit will be required if after installation the circuit breaker trips or fuse blows on a regular...

Page 9: ...ve junction box cover and secure with a wire clamp not supplied Figure 3 6 Connect the black wire live from the unit to the black wire from power supply Figure 3 7 Connect the white wire neutral from...

Page 10: ...the temperature to your individual requirements turn the thermostat control clockwise all the way to turn on the heater When the room reaches the de sired temperature turn the ther mostat knob counte...

Page 11: ...er Remote Control Initializa tion Reprogramming In the event that your remote control ceases to operate your fireplace follow these steps to re initialize the remote control and the remote control rec...

Page 12: ...the log ember bed exterior disappears There are 2 bulbs under the log set which generate the flames and embers Light Bulb Requirements Quantity of 2 clear chandelier or candelabra bulbs with an E 12 s...

Page 13: ...irebox some force may be nec essary to remove 3 Set log set in front of fire place Figure 7 Side Section Front Edge Log Ember Bed Back Ledge Rear Tab Maintenance 4 Disconnect the flicker rod from the...

Page 14: ...ass should be completely dried with a lint free cloth to prevent water spots To prevent scratching do not use abrasive cleaners or spray liquids on the glass surface Fireplace Surface Cleaning To remo...

Page 15: ...ts such products to be free from Warranty defects in material and workmanship for a period of 2 years from the date of the first purchase of such products as follows a a repair or replacement warranty...

Page 16: ...of repair or replacement choose to refund the purchase price for such product or part This limited warranty entitles the purchaser to on site or in home war ranty services Accordingly Dimplex will be...

Page 17: ...s What Dimplex and its dealers and service agents are also not responsible for IN NO EVENT WILL DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY WHETHER IN CON...

Page 18: ...ion Switch 2800071100RP Power Cord 4100040900RP Partially Reflective Glass 5901410200RP Control Knob 8801080100RP Stainless Steel Trim Assembly 1020230280RP Gloss Black Trim Assembly 1020230104RP Flat...

Reviews: